Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(26)
FUJITSU
(73)
Fujitsu Atlantic
(31)
GENERAL
(31)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(51)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(2)
MIDEA
(0)
MITSUBISHI ELECTRIC
(269)
Mitsubishi Heavy Industries
(93)
NORD
(0)
Nobu
(0)
PANASONIC
(86)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(23)
THERMOR
(0)
TOSHIBA
(88)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(8)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-SM140VKA3/PEAD-SM140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA3/PEAD-SM140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PEAD-SM140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PEAD-SM140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA2/PEAD-SM140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA2/PEAD-SM140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
RAV-GV1401AT8P-E/RAV-HM1401UTP-E
DIC 3ph
|
TOSHIBA | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.00 | -15° | 12.10 | 7.80 | |
|
AC250KNHPKH / AC250KXAPNH
CAC
|
SAMSUNG | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.00 | 3.40 | 3.24 | -20° | 25.00 | 18.50 | |
|
PUHZ-SHW230YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.81 | 3.51 | 3.47 | -25° | 19.00 | 23.00 | |
|
RAV-GV1401ATP-E/RAV-HM1401UTP-E
DIC
|
TOSHIBA | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.13 | -15° | 11.50 | 7.80 | |
|
PUZ-SM140VKA2/PLA-SM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.91 | 3.30 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA2/PLA-SM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.91 | 3.30 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA3/PLA-SM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.91 | 3.30 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PLA-SM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.91 | 3.30 | -15° | 13.40 | 9.40 | |
|
U-140PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.78 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
RAV-GM1602AT8W-E/RAV-HM1601FT-E
DI 3ph
|
TOSHIBA | Floor standing | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.82 | 2.83 | -15° | 14.00 | 8.30 | |
|
U-140PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
RAV-GV1401AT8P-E+RAV-HM1401BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.00 | -15° | 12.10 | 7.80 | |
|
FDC100VNX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
FDC100VSX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
RAV-GV1101ATP-E/RAV-HM1101BTP-E
DIC
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.33 | -15° | 9.50 | 7.60 | |
|
RPFC-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.82 | 2.88 | -15° | 9.80 | 7.90 | |
|
RAV-GV1401ATP-E/RAV-HM1401BTP-E
DIC
|
TOSHIBA | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.05 | -15° | 11.50 | 7.80 | |
|
PUZ-SM125VKA3/PEAD-SM125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA3/PEAD-SM125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA3/PEAD-SM125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA3/PEAD-SM125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA2/PEAD-SM125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA2/PEAD-SM125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
AC200KNHPKH / AC200KXAPNH
CAC
|
SAMSUNG | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.50 | 3.45 | -20° | 20.00 | 17.50 | |
|
FDC100VSX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.88 | 3.84 | 3.20 | -20° | 10.00 | 10.70 | |
|
RAV-GV1101AT8P-E/RAV-HM1101BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.80 | 3.40 | -15° | 9.50 | 7.60 | |
|
AOYG36KATA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG36KATA/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/ABEG36KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/ABEG36KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KATA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
PUZ-SM125VKA2/PLA-SM125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.73 | 3.94 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA2/PLA-SM125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.73 | 3.94 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA3/PLA-SM125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.73 | 3.94 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA3/PLA-SM125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.73 | 3.94 | 3.61 | -15° | 12.10 | 8.50 | |
|
U-125PZH4E5 / S-2545PK4E(3x)
2024
|
PANASONIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.79 | 3.71 | -20° | 12.20 | 9.50 | |
|
U-125PZH4E8 / S-2545PK4E(3x)
2024
|
PANASONIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.79 | 3.71 | -20° | 12.20 | 9.50 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401FT-E
DI 3ph
|
TOSHIBA | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 4.86 | 3.90 | 3.24 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401FT-E
DI
|