Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(22)
BRYANT
(0)
Buderus
(4)
CARRIER
(50)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(270)
EQUATION
(0)
FUJI ELECTRIC
(138)
FUJITSU
(332)
Fujitsu Atlantic
(165)
GENERAL
(210)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(140)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(14)
MIDEA
(33)
MITSUBISHI ELECTRIC
(456)
Mitsubishi Heavy Industries
(143)
NORD
(0)
Nobu
(0)
PANASONIC
(313)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(98)
THERMOR
(0)
TOSHIBA
(301)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(8)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
CU-BZ25ZKE / CS-BZ25ZKE
2023
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.30 | 4.09 | -15° | 2.50 | 1.90 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
RAV-GM1401ATP-E1/RAV-HM1401UTP-E
DI
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
RXF20E / FTXF20E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
RXF20F / FTXF20F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
AR40H18C1AMN/AR40H18C1AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0AMN/AR40F18C0AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0BMN/AR40F18C0BMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
RXF42E / FTXF42E
RXF
|
DAIKIN | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.71 | -15° | 4.20 | 3.30 | |
|
RXF42F / FTXF42F
RXF
|
DAIKIN | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.71 | -15° | 4.20 | 3.30 | |
|
CU-UZ50CKE / CS-UZ50CKE
2025
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
RXF50F / FTXF50F
RXF
|
DAIKIN | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -15° | 5.00 | 3.80 | |
|
CU-BZ60ZKE / CS-BZ60ZKE
2023
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.16 | -15° | 6.00 | 4.40 | |
|
CU-BZ60CKE / CS-BZ60CKE
2025
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.16 | -15° | 6.00 | 4.40 | |
|
AOEH07KLTA/ASEH07KLTA
ASE**K
|
FUJITSU | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOHH07KLTA/ASHH07KLTA
ASH**K
|
GENERAL | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
ROH07KLTA/RSH07KLTA
RS**K
|
FUJI ELECTRIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOHH07KLTA/ASHH07KLTBL
ASH**K
|
GENERAL | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOEH07KLTA/ASEH07KLTBL
ASE**K
|
FUJITSU | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
RAS-2.5HVRC3 / RPK-2.5FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.04 | 3.94 | 3.71 | -25° | 5.60 | 5.20 | |
|
5MWXM90A9 / FTXM71A / FTXM20A
5MWXM
|
DAIKIN | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.58 | 4.08 | 3.27 | -15° | 8.00 | 4.50 | |
|
5MWXM90A9 / FTXM71A / CTXM15A
5MWXM
|
DAIKIN | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.58 | 4.08 | 3.27 | -15° | 8.00 | 4.50 | |
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
RAS-13J2AVSG-E1/RAS-B13J2FVG-E
Console
|
TOSHIBA | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 4.54 | 3.31 | -15° | 3.50 | 3.00 | |
|
MXZ-2D42VA2/MSZ-EF18VE3W(B)(S)/MSZ-EF25VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.84 | -15° | 4.20 | 3.20 | |
|
RAV-GV801ATP-E/RAV-HM801UTP-E
DIC
|
TOSHIBA | Cassette | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.15 | 3.68 | -15° | 6.70 | 4.80 | |
|
CU-TZ71ZKE / CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.71 | -15° | 7.10 | 5.50 | |
|
AC120RXADKG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.42 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.48 | -20° | 12.00 | 6.50 | |
|
PUZ-M125VKA2/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA3/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
MOX301-18HFN8-QRD0GW/MSAGCU-18HRFNX-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
GFCAGCU-18HRFN8/GFCAGCU-18HRFN8
Extreme save R32
|
CONFORT AIR | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOD-18N8D0/MAG1-18N8
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOM-18N8D0/MAG2-18N8
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOM-18N8D0-1/MAG2-18N8-1
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AC166i.2-5,3 / AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
Ν2UVO-18/Ν2UVI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOX301-18HFN8-QRD0GW/MSAGCU-18HRFNX-QRD0GW-CARBON
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
X3BP-18N8D0-O/AGF-18NXD1-I
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N2VOCP-18/Ν2VICP-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 |