Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(22)
BRYANT
(0)
Buderus
(4)
CARRIER
(50)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(270)
EQUATION
(0)
FUJI ELECTRIC
(138)
FUJITSU
(332)
Fujitsu Atlantic
(165)
GENERAL
(210)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(140)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(14)
MIDEA
(33)
MITSUBISHI ELECTRIC
(456)
Mitsubishi Heavy Industries
(143)
NORD
(0)
Nobu
(0)
PANASONIC
(313)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(98)
THERMOR
(0)
TOSHIBA
(301)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(8)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-60PZ3E5A / S-60PY3E
2022
|
PANASONIC | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.61 | -15° | 6.00 | 4.60 | |
|
U-50PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
RAC-DJ35WHAE / RAK-DJ35RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 4.00 | -15° | 3.50 | 2.80 | |
|
PUZ-ZM250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.13 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
RAV-GM562ATP-E/RAV-HM561MUTP-E
DI
|
TOSHIBA | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.40 | 3.61 | -15° | 5.00 | 2.80 | |
|
FDC100VSA-W/SRK100ZR-W
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/SRK100ZR-WF
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/SRK100ZR-WF
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
RAS-18J2AVSG-E1/RAS-B18J2FVG-E
Console
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 2.93 | -15° | 5.00 | 4.00 | |
|
AOYG36LATT/AUYG36LRLA
AUY**L
|
FUJITSU | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.38 | -15° | 10.00 | 10.00 | |
|
RAC-DJ25WHAE / RAK-DJ25RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.65 | -15° | 2.50 | 2.47 | |
|
ARXP35N / ATXP35N
ARXP
|
DAIKIN | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.62 | 4.02 | -15° | 3.50 | 2.80 | |
|
ARXP35N9 / ATXP35N9
ARXP
|
DAIKIN | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.62 | 4.02 | -15° | 3.50 | 2.80 | |
|
RAS-4M27G3AVG-E/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
38WH4M080C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
RAS-4M27G3AVG-E/RAS-B13P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
RAS-16CAVG-E/RAS-B16CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.73 | -15° | 4.20 | 3.60 | |
|
RAS-16E2AVG-E/RAS-B16E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.73 | -15° | 4.20 | 3.60 | |
|
RAS-16E2AVG-E/RAS-B16S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.73 | -15° | 4.20 | 3.60 | |
|
38WHSM042A1A0TEE/40WHMW042D1A0TEE
40WHM
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.73 | -15° | 4.20 | 3.60 | |
|
RZAG60A / FTXM60R
RZAG
|
DAIKIN | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.35 | 3.61 | -20° | 6.00 | 4.60 | |
|
RAV-GM1602AT8W-E/RAV-HM1601CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.22 | 3.41 | -15° | 14.00 | 8.00 | |
|
MUZ-SF50VEH/MSZ-SF50VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.41 | -20° | 5.00 | 4.20 | |
|
RXM50R / FBA50A9
RXM
|
DAIKIN | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.27 | 4.06 | 3.83 | -15° | 5.00 | 4.40 | |
|
RXM50A / FBA50A9
RXM
|
DAIKIN | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.27 | 4.06 | 3.83 | -15° | 5.00 | 4.40 | |
|
PUZ-ZM71VHA2/PEAD-M35JA2/PEAD-M35JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA2/PEAD-M35JAL2/PEAD-M35JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M35JA3/PEAD-M35JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M35JAL3/PEAD-M35JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-SM100VKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
RXP50N8 / FTXP50N9
RXP
|
DAIKIN | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.71 | -15° | 5.00 | 4.60 | |
|
PUZ-ZM140YDA2/PLA-M140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.14 | 3.50 | -20° | 13.40 | 10.60 | |
|
RAC-DJ50WHAE / RAK-DJ50RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.50 | 3.71 | -15° | 5.00 | 4.35 | |
|
CU-2Z50TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.63 | -15° | 5.00 | 4.20 | |
|
FDC100VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.13 | 4.08 | -15° | 10.00 | 6.40 | |
|
FDC100VNP-W/FDUM100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.13 | 4.08 | -15° | 10.00 | 6.40 | |
|
PUZ-M140YKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140YKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-ZM140YDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
RAV-GP1601AT8-E/RAV-HM1601FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.98 | 3.31 | -20° | 14.00 | 12.00 | |
|
RAV-GM1102ATW-E/RAV-HM1101KRTP-E
DI
|
TOSHIBA | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.26 | -15° | 9.50 | 8.00 | |
|
U-71PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.30 | 4.20 | -15° | 6.80 | 4.70 | |
|
U-50PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.10 | 3.73 | -15° | 5.00 | 4.00 | |
|
CU-Z50CBEA / CS-Z50CD3EAW
2025
|
PANASONIC | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
CU-Z50UBEA / CS-Z50UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 3.03 | -15° | 5.00 | 3.80 |