Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(22)
BRYANT
(0)
Buderus
(4)
CARRIER
(50)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(270)
EQUATION
(0)
FUJI ELECTRIC
(138)
FUJITSU
(332)
Fujitsu Atlantic
(165)
GENERAL
(210)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(140)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(14)
MIDEA
(33)
MITSUBISHI ELECTRIC
(456)
Mitsubishi Heavy Industries
(143)
NORD
(0)
Nobu
(0)
PANASONIC
(313)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(98)
THERMOR
(0)
TOSHIBA
(301)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(8)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC100VNX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
PUZ-ZM125VDA/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
MUZ-RW50VGHZ / MSZ-RW50VG
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.10 | -30° | 5.00 | 6.00 | |
|
MUZ-RW50VGHZ2/MSZ-RW50VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.10 | -30° | 5.00 | 6.00 | |
|
U-60PZ3E5A / S-6071PF3E
2021
|
PANASONIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.04 | -15° | 5.70 | 4.40 | |
|
SRC60ZSX-W3/FDUM60VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.43 | 4.37 | 3.83 | -20° | 5.60 | 4.70 | |
|
RAC-25FXE / RAF-25RXE
RAC-FXE
|
HITACHI | Floor standing | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -20° | 2.50 | 2.85 | |
|
RXM35R9 / FTXM35R
RXM
|
DAIKIN | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.65 | 5.10 | 4.04 | -20° | 3.40 | 2.50 | |
|
SRC60ZSX-W3/FDE60VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.72 | 4.41 | 3.60 | -20° | 5.60 | 4.50 | |
|
FDC100VNA-W/SRK50ZSX-W/SRK50ZSX-W
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.05 | 4.47 | 4.29 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/SRK50ZSX-W/SRK50ZSX-W
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.05 | 4.47 | 4.29 | -20° | 10.00 | 8.50 | |
|
FDC90VNP-W/FDE100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.78 | 4.46 | 4.52 | -15° | 9.00 | 5.80 | |
|
RAS-2M14G3AVG-E/RAS-B13G3KVSG-E+RAS-B13G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.89 | -20° | 4.00 | 3.10 | |
|
38WH2M040C1A0TEE/40WHHW035D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.89 | -20° | 4.00 | 3.10 | |
|
RAS-2M14G3AVG-E/RAS-B13P2KVSG-E+RAS-B13P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.89 | -20° | 4.00 | 3.10 | |
|
RAS-2M60S4AVG-ND/RAS-B25G3KVSG-ND+RAS-B50G3KVSG-ND
Multi
|
TOSHIBA | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 3.74 | -25° | 6.00 | 6.50 | |
|
CU-2Z50ABEC/CS-HZ25ZKE/CS-HZ25ZKE
2024
|
PANASONIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.60 | 4.71 | -25° | 5.30 | 5.20 | |
|
FDC100VNA-W/FDT100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.08 | 4.60 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDT100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.08 | 4.60 | 4.41 | -20° | 10.00 | 8.50 | |
|
RXM25R9 / FTXM25R
RXM
|
DAIKIN | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.65 | 5.10 | 5.00 | -20° | 2.50 | 2.40 | |
|
U-125PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.20 | 3.46 | -20° | 12.10 | 9.30 | |
|
RAM-G55N2HAE / RAK-XJ18QHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.20 | -15° | 5.50 | 5.60 | |
|
RAM-G55N2HBE / RAK-XJ18QHAE / RAK-XJ35RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.20 | -15° | 5.50 | 5.60 | |
|
RAC-35FXE / RAF-35RXE
RAC-FXE
|
HITACHI | Floor standing | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.90 | -20° | 3.50 | 3.53 | |
|
AOYG14KBTA2/ASYG07KGTB/ASYG07KGTB
AOY**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
ROG14KBTA2/RSG07KGTB/RSG07KGTB
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
AOHG14KBTA2/ASHG07KGTB/ASHG07KGTB
AOH**K Multi
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
AOEG14KBCA2/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
AOYG14KBTA2/ASYH07KGTG/ASYH07KGTG
AOY**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
AOHG14KBTA2/ASHH07KGTG/ASHH07KGTG
AOH**K Multi
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
AOYG14KBTA2/ASYG07KGTB/ASYG07KGTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
U-125PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.12 | 4.20 | 3.46 | -20° | 12.10 | 9.30 | |
|
AOEG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG12KBTB/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXH12KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
RXM50A8 / FTXM50A
RXM
|
DAIKIN | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.55 | 4.75 | 4.00 | -20° | 5.00 | 4.50 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.92 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
AC052RXADKG/AC052RN4DKG
CAC
|
SAMSUNG | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.30 | 4.03 | -20° | 5.00 | 2.60 | |
|
PUZ-ZM100YDA/PEAD-M100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA/PEAD-M100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
AOYH12KJCA/ASYH12KJCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOYH12KJCA/ASYH12KJCA-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOHH12KJCA/ASHH12KJCA
ASH**K
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 |