Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(6)
BRYANT
(0)
Buderus
(0)
CARRIER
(10)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(18)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(10)
Fujitsu Atlantic
(4)
GENERAL
(14)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(10)
IVT
(0)
Inventor
(2)
KAYSUN
(0)
LG
(0)
MIDEA
(8)
MITSUBISHI ELECTRIC
(20)
Mitsubishi Heavy Industries
(4)
NORD
(0)
Nobu
(0)
PANASONIC
(43)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(3)
THERMOR
(0)
TOSHIBA
(45)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(2)
YORK
(0)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
RAS-4M27G3AVG-E/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
38WH4M080C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
RAS-4M27G3AVG-E/RAS-B13P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
MUZ-EF25VEH/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
MOX201-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
X2AGN-09N8D6-OH/AGN-09N8D1-IH
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
WITO-09322.MH/WIT-09322.MH
WIT
|
WESTPOINT | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AITO-09322.MH/AIT-09322.MH
AIT
|
AIRCLASS | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
RAS-4M27G3AVG-E/RAS-B16G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
RAS-4M27G3AVG-E/RAS-B16P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
CU-NZ25YKE / CS-NZ25YKE
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-NZ25YKE / CS-NZ25YKE-1
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
RAS-2M14G3AVG-E/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.20 | 4.70 | 4.68 | -20° | 4.00 | 3.10 | |
|
38WH2M040C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.20 | 4.70 | 4.68 | -20° | 4.00 | 3.10 | |
|
RAS-2M14G3AVG-E/RAS-B13P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.20 | 4.70 | 4.68 | -20° | 4.00 | 3.10 | |
|
RAS-25G3AVSG-ND/RAS-B25N4KVRG-ND
HAORI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
RAS-25G3AVSG-ND/RAS-B25G3KVSG-ND
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
RAS-25G3AVSG-ND/RAS-B25G3KVSGB-ND
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
RAS-4M27G3AVG-E/RAS-B16G3KVSG-E+RAS-B13G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
RAS-4M27G3AVG-E/RAS-B16G3KVSG-E+RAS-B16G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
RAS-4M27G3AVG-E/RAS-B16P2KVSG-E+RAS-B13P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
RAS-4M27G3AVG-E/RAS-B16P2KVSG-E+RAS-B16P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.74 | 4.50 | 4.74 | -20° | 8.00 | 5.20 | |
|
MOX230-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
GFCAGBU-09HRFN8-PRO/GFCAGBU-09HRFN8-PRO
Extreme save R32
|
CONFORT AIR | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOD-09N8D6/MAG1-07N8
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOD-09N8D6/MAG1-09N8
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
ΝECUVO-09/ΝECUVI-09WFI
Neo Eco
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOX230-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)-CARBON
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOX2-09HFN8CD/MSAG-09HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MCX2-09HFN8CD/MCAG-09HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
NPVO-09/NPVI-09WFI
Neo Plus
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
WIMO-09326.MH / WIM-09326.MH
WIM 326
|
WESTPOINT | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MUZ-EF25VGH2/MSZ-EF25VGK2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.10 | 4.60 | 4.57 | -20° | 2.50 | 2.50 | |
|
MUZ-EF25VGH/MSZ-EF25VG(K)(W)(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.10 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
RAV-GP1101AT8-E/RAV-HM1101UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.32 | 4.38 | 4.65 | -20° | 10.00 | 9.50 | |
|
RAS-35G3AVSG-ND/RAS-B35G3KVSG-ND
SHORAI
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 5.10 | 4.57 | -25° | 3.50 | 3.60 | |
|
RAS-35G3AVSG-ND/RAS-B35G3KVSGB-ND
SHORAI
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 5.10 | 4.57 | -25° | 3.50 | 3.60 | |
|
RAS-10P2AVSG-E/RAS-B10N4KVRG-E2
HAORI
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.57 | -20° | 2.50 | 2.50 | |
|
RAS-2M10G3AVG-E/RAS-B10G3KVSG-E+RAS-B07G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAS-2M10G3AVG-E/RAS-B10G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
38WH2M033C1A0TEE/40WHHW025D1A0TEE/40WHHW020D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
38WH2M033C1A0TEE/40WHHW025D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 |