Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(24)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(45)
Mitsubishi Heavy Industries
(42)
NORD
(0)
Nobu
(0)
PANASONIC
(31)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(10)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC250KNHPKH / AC250KXAPNH
CAC
|
SAMSUNG | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.00 | 3.40 | 3.24 | -20° | 25.00 | 18.50 | |
|
PUHZ-SHW230YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.81 | 3.51 | 3.47 | -25° | 19.00 | 23.00 | |
|
FDC100VNX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
FDC100VSX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
AC200KNHPKH / AC200KXAPNH
CAC
|
SAMSUNG | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.50 | 3.45 | -20° | 20.00 | 17.50 | |
|
FDC100VSX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.88 | 3.84 | 3.20 | -20° | 10.00 | 10.70 | |
|
PUZ-M200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.48 | 3.61 | 3.40 | -20° | 19.00 | 15.50 | |
|
FDC100VSX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
FDC100VNX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
FDC100VSX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.17 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
U-200PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.07 | 3.87 | 3.71 | -20° | 16.00 | 15.70 | |
|
U-140PZH4E5 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
PUZ-M200YDA/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.77 | 3.40 | -20° | 19.00 | 15.50 | |
|
FDC100VNX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
PUZ-M250YDA/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 3.59 | 3.30 | -20° | 22.00 | 17.00 | |
|
PUZ-M250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.39 | 3.56 | 3.30 | -20° | 22.00 | 20.20 | |
|
PUZ-M250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.03 | 4.16 | 3.19 | -20° | 22.00 | 20.20 | |
|
PUZ-ZM250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
PUZ-ZM250YKA3/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
RAS-5HNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
U-200PZH4E8 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.41 | 3.89 | 3.71 | -20° | 17.50 | 15.70 | |
|
RAS-5HNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.67 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
PUZ-ZM200YKA3/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.61 | 3.50 | -20° | 19.00 | 18.90 | |
|
PUZ-ZM200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.62 | 3.50 | -20° | 19.00 | 18.90 | |
|
RAS-5HVNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
FDC100VNX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.92 | 4.16 | 3.20 | -20° | 10.00 | 11.20 | |
|
RAV-GP1601AT8-E/RAV-HM1601BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.81 | 3.96 | 3.50 | -20° | 14.00 | 12.00 | |
|
RAS-5HVNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
RAS-5HRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
FDC100VNX-W/FDF100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.81 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDF100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.80 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDF100VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.81 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDF100VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.80 | -20° | 10.00 | 11.20 | |
|
RAV-GP1401AT8-E1/RAV-HM1401BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.98 | 3.83 | -20° | 12.50 | 11.80 | |
|
FDC100VNX-W/FDUM50VH/FDUM50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.88 | 3.79 | -20° | 10.00 | 10.00 | |
|
FDC100VSX-W/FDUM50VH/FDUM50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.88 | 3.79 | -20° | 10.00 | 10.00 | |
|
RAS-5HVRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
U-250PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.75 | 3.55 | -20° | 22.00 | 17.20 | |
|
FDC100VSX/FDU100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.19 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VSX/FDUM100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.19 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VNX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VSX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VNX/FDU100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VNX/FDUM100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
RAS-5HNC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.13 | 4.23 | 3.98 | -20° | 11.90 | 11.93 |