Filters · 2 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(10)
BRYANT
(0)
Buderus
(0)
CARRIER
(18)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(2)
Candy
(0)
DAIKIN
(43)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(20)
Fujitsu Atlantic
(8)
GENERAL
(28)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(43)
IVT
(0)
Inventor
(4)
KAYSUN
(0)
LG
(0)
MIDEA
(15)
MITSUBISHI ELECTRIC
(152)
Mitsubishi Heavy Industries
(50)
NORD
(0)
Nobu
(0)
PANASONIC
(113)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(48)
THERMOR
(0)
TOSHIBA
(108)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(5)
YORK
(0)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-25E2AVG-ND/RAS-B25E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.45 | 4.27 | -25° | 2.50 | 2.80 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ35WKE / CS-CZ35WKE
2020
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.08 | -25° | 3.50 | 3.60 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
RAS-35E2AVG-ND/RAS-B35E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.50 | 3.89 | -25° | 3.50 | 3.40 | |
|
RAS-35G3AVSG-ND/RAS-B35G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.77 | -25° | 3.50 | 3.60 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 | |
|
MUZ-SF35VEH/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.88 | -20° | 3.50 | 2.90 | |
|
PUZ-ZM60VHA2/PKA-M60KAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/PKA-M60KA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PKA-M60KA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PKA-M60KAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
AC026BXAPKG/AC026BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.33 | -25° | 2.60 | 2.00 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
CU-Z71ZKE / CS-Z71ZKEW
2023
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -20° | 7.10 | 5.50 | |
|
CU-Z71CKE / CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -20° | 7.10 | 5.50 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
CU-Z42ZKE / CS-Z42ZKEW
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-Z42ZKE / CS-XZ42ZKEW-H
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-Z42CKE / CS-Z42CKEW-H
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-Z42CKE / CS-XZ42CKEW-H
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
MUZ-SF25VEH/MSZ-SF25VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.30 | 4.10 | -20° | 2.50 | 2.40 | |
|
FDC100VNX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VSX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
RAS-5HNC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.13 | 4.23 | 3.98 | -20° | 11.90 | 11.93 | |
|
RAV-GP561ATW-E/RAV-HM561FT-E
SDI
|
TOSHIBA | Floor standing | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.21 | 3.39 | -27° | 5.00 | 3.80 | |
|
PUZ-ZM71VHA2/PKA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.78 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA2/PKA-M71KAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.78 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PKA-M71KA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.78 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PKA-M71KAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.78 | -20° | 7.10 | 4.70 | |
|
AC071BXAPKG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
AC071BXAPNG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
RXM60R / FTXM60R
RXM
|
DAIKIN | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.61 | -20° | 6.00 | 4.80 | |
|
RXM60A / FTXM60A
RXM
|
DAIKIN | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.61 | -20° | 6.00 | 4.80 | |
|
FDC100VNA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
PUZ-ZM250YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.12 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
RAS-5HVNC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.24 | 3.98 | -20° | 11.90 | 11.93 | |
|
RAS-5HRC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.37 | 4.25 | 3.98 | -20° | 11.90 | 11.93 | |
|
PUZ-ZM250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.13 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
FDC100VSA-W/SRK100ZR-W
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/SRK100ZR-WF
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/SRK100ZR-WF
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
RAS-4M27G3AVG-E/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 |