Filters · 5 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(12)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(34)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(76)
Mitsubishi Heavy Industries
(51)
NORD
(0)
Nobu
(0)
PANASONIC
(37)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(34)
THERMOR
(0)
TOSHIBA
(17)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC250KNHPKH / AC250KXAPNH
CAC
|
SAMSUNG | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.00 | 3.40 | 3.24 | -20° | 25.00 | 18.50 | |
|
AC200KNHPKH / AC200KXAPNH
CAC
|
SAMSUNG | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.50 | 3.45 | -20° | 20.00 | 17.50 | |
|
PUZ-M200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.48 | 3.61 | 3.40 | -20° | 19.00 | 15.50 | |
|
FDC100VSX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.11 | 3.87 | 3.71 | -20° | 10.00 | 8.20 | |
|
FDC100VSX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
PUZ-ZM71VHA2/PCA-M71HA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71HA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
FDC100VNX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
PUZ-M200YDA/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.77 | 3.40 | -20° | 19.00 | 15.50 | |
|
FDC100VNX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 3.88 | 3.71 | -20° | 10.00 | 8.20 | |
|
PUZ-M250YDA/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 3.59 | 3.30 | -20° | 22.00 | 17.00 | |
|
RZAG60A / FDXM60F9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
RZAG60A / FNA60A9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
SRC50ZSX-W3/FDUM50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.89 | 3.39 | -20° | 5.00 | 3.70 | |
|
PUZ-M250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.39 | 3.56 | 3.30 | -20° | 22.00 | 20.20 | |
|
RZAG50A / FDXM50F9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
RZAG50A / FNA50A9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
PUZ-ZM250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
PUZ-ZM250YKA3/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
FDC100VNA/FDUM50VH/FDUM50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.94 | 3.49 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM50VH/FDUM50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.94 | 3.49 | -20° | 10.00 | 8.50 | |
|
AC071RXADKG/AC071BNLDKG
CAC
|
SAMSUNG | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.36 | -20° | 7.10 | 3.70 | |
|
PUZ-ZM71VHA2/SEZ-M71DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA2/SEZ-M71DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/SEZ-M71DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
AC120RXADKG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.42 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.48 | -20° | 12.00 | 6.50 | |
|
AC120RXADKG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.47 | -20° | 12.00 | 6.50 | |
|
AC100RXADKG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.20 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.27 | -20° | 10.00 | 5.20 | |
|
RAS-5HNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAS-5HNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.67 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
AC140RXADKG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
SRC40ZSX-W1/FDUM40VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.81 | 4.09 | -20° | 4.00 | 3.00 | |
|
PUZ-ZM200YKA3/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.61 | 3.50 | -20° | 19.00 | 18.90 | |
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
SRC50ZSX-W3/FDE50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.07 | 3.70 | -20° | 5.00 | 3.80 |