Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(14)
BRYANT
(0)
Buderus
(4)
CARRIER
(21)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(56)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(20)
Fujitsu Atlantic
(8)
GENERAL
(28)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(76)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(0)
MIDEA
(33)
MITSUBISHI ELECTRIC
(244)
Mitsubishi Heavy Industries
(116)
NORD
(0)
Nobu
(0)
PANASONIC
(143)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(92)
THERMOR
(0)
TOSHIBA
(124)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(0)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
SRC40ZSX-W1/FDUM40VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.81 | 4.09 | -20° | 4.00 | 3.00 | |
|
PUZ-ZM200YKA3/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.61 | 3.50 | -20° | 19.00 | 18.90 | |
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
SRC50ZSX-W3/FDE50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.07 | 3.70 | -20° | 5.00 | 3.80 | |
|
FDC100VNA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
RAS-35E2AVG-ND/RAS-B35E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.50 | 3.89 | -25° | 3.50 | 3.40 | |
|
PUZ-ZM200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.62 | 3.50 | -20° | 19.00 | 18.90 | |
|
RAS-4HNC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.51 | 4.17 | 3.53 | -20° | 10.00 | 8.70 | |
|
RAS-5HVNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.70 | 4.12 | 3.47 | -20° | 10.00 | 8.70 | |
|
FDC100VNX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.92 | 4.16 | 3.20 | -20° | 10.00 | 11.20 | |
|
RAV-GP1601AT8-E/RAV-HM1601BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.81 | 3.96 | 3.50 | -20° | 14.00 | 12.00 | |
|
RAS-35G3AVSG-ND/RAS-B35G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.77 | -25° | 3.50 | 3.60 | |
|
PUZ-ZM71VHA2/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.25 | -20° | 7.10 | 4.80 | |
|
AC140RXADKG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.35 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.41 | -20° | 13.40 | 8.40 | |
|
RAS-5M34G3AVG-E1/RAS-B16G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
RAS-5M34G3AVG-E1/RAS-B16P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 | |
|
RAS-5HVNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
MUZ-SF35VEH/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.88 | -20° | 3.50 | 2.90 | |
|
RAS-5HRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
RAS-24P2AVSG-E/RAS-B24P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.40 | -20° | 7.00 | 6.30 | |
|
RAS-24P2AVSG-E/RAS-B24P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.40 | -20° | 7.00 | 6.30 | |
|
RAS-4HVNC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.72 | 4.18 | 3.53 | -20° | 10.00 | 8.70 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
MUFZ-KW35VGHZ2/MFZ-KW35VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
PUZ-ZM60VHA2/PKA-M60KAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/PKA-M60KA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PKA-M60KA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PKA-M60KAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
AC026BXAPKG/AC026BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.33 | -25° | 2.60 | 2.00 | |
|
FDC100VNX-W/FDF100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.81 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDF100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.80 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDF100VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.81 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDF100VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.80 | -20° | 10.00 | 11.20 | |
|
RAV-GP1401AT8-E1/RAV-HM1401BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.98 | 3.83 | -20° | 12.50 | 11.80 | |
|
AC071RXADKG/AC071RNMDKG
CAC
|
SAMSUNG | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.20 | -20° | 6.80 | 3.70 | |
|
FDC100VNX-W/FDUM50VH/FDUM50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.88 | 3.79 | -20° | 10.00 | 10.00 | |
|
FDC100VSX-W/FDUM50VH/FDUM50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.88 | 3.79 | -20° | 10.00 | 10.00 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
FDC100VNA-W/FDUM50VH/FDUM50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.00 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDUM50VH/FDUM50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.00 | 3.68 | -20° | 10.00 | 8.50 | |
|
CU-Z71ZKE / CS-Z71ZKEW
2023
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -20° | 7.10 | 5.50 |