Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(14)
BRYANT
(0)
Buderus
(4)
CARRIER
(21)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(56)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(20)
Fujitsu Atlantic
(8)
GENERAL
(28)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(76)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(0)
MIDEA
(33)
MITSUBISHI ELECTRIC
(244)
Mitsubishi Heavy Industries
(116)
NORD
(0)
Nobu
(0)
PANASONIC
(143)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(92)
THERMOR
(0)
TOSHIBA
(124)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(0)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC100VSX-W/FDTC50VH/FDTC50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.58 | 4.16 | 3.69 | -20° | 10.00 | 11.20 | |
|
PUZ-ZM140VDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.67 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
MUFZ-KW25VGHZ2/MFZ-KW25VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
RZAG60A / FCAG60B
RZAG
|
DAIKIN | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.25 | 3.40 | -20° | 6.00 | 4.60 | |
|
RAS-18P2AVSG-E/RAS-B18J2FVG-E1
Console
|
TOSHIBA | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.00 | -20° | 5.00 | 4.00 | |
|
MUZ-SF42VEH/MSZ-SF42VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.30 | 3.42 | -20° | 4.20 | 3.80 | |
|
AC071RXADKG/AC071RN4DKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.27 | -20° | 7.10 | 4.50 | |
|
AC071RXADKG/AC071RN4PKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.23 | -20° | 7.10 | 4.50 | |
|
MUZ-AY20VG/MSZ-AY20VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
MUZ-AY20VG2/MSZ-AY20VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
FDC100VNA-W/FDTC50VH/FDTC50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.17 | 4.38 | 3.67 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDTC50VH/FDTC50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.17 | 4.38 | 3.67 | -20° | 10.00 | 8.50 | |
|
AC035RXADKG/AC035RNMDKG
CAC
|
SAMSUNG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.48 | -20° | 3.50 | 2.00 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
FDC100VNA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
RAS-3M18G3AVG-E/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.72 | -20° | 5.20 | 3.50 | |
|
38WH3M052C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.72 | -20° | 5.20 | 3.50 | |
|
RAS-3M18G3AVG-E/RAS-B13P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.72 | -20° | 5.20 | 3.50 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
RZAG35A / FTXM35R
RZAG
|
DAIKIN | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 3.85 | -20° | 3.50 | 2.60 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
RAS-5HVRC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.26 | 3.98 | -20° | 11.90 | 11.93 | |
|
AC035BXAPKG/AC035BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.04 | -25° | 3.50 | 2.50 | |
|
RAS-2HVRC3 / RCI-2.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.08 | 4.23 | -25° | 5.00 | 5.00 | |
|
PUZ-ZM60VHA2/PCA-M60KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.01 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PCA-M60KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.01 | -20° | 6.10 | 4.40 | |
|
RAS-5HRC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.89 | 4.03 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAS-3M18G3AVG-E/RAS-B16G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
38WH3M052C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
RAS-3M18G3AVG-E/RAS-B16P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
FDC100VNX-W/SRK100ZR-W
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.01 | 3.69 | -20° | 10.00 | 10.50 | |
|
FDC100VSX-W/SRK100ZR-W
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.01 | 3.69 | -20° | 10.00 | 10.50 | |
|
FDC100VSX-W/SRK100ZR-WF
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.01 | 3.69 | -20° | 10.00 | 10.50 | |
|
FDC100VNX-W/SRK100ZR-WF
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.01 | 3.69 | -20° | 10.00 | 10.50 | |
|
FDC71VNX-W/FDF71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDF71VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
FDC100VNA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
PUZ-ZM100YDA/PEAD-M50JA2/PEAD-M50JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA/PEAD-M50JAL2/PEAD-M50JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M50JA3/PEAD-M50JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M50JAL3/PEAD-M50JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
MFZ-KW25VG/MUFZ-KW25VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
RZAG60A / FBA60A9
RZAG
|
DAIKIN | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.10 | 3.80 | -20° | 6.00 | 4.50 | |
|
MUZ-FT50VGHZ/MSZ-FT50VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.30 | 3.85 | -25° | 5.00 | 5.00 | |
|
MUZ-FT50VGHZ2/MSZ-FT50VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.30 | 3.85 | -25° | 5.00 | 5.00 | |
|
RAS-13P2AVSG-E/RAS-B13J2FVG-E1
Console
|
TOSHIBA | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.70 | 3.89 | -20° | 3.50 | 3.00 | |
|
CLC6101i 65 HE / CLC6101i-W 65 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 4.20 | -20° | 3.50 | 3.20 |