Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(6)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(9)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(6)
Fujitsu Atlantic
(0)
GENERAL
(6)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(2)
KAYSUN
(0)
LG
(0)
MIDEA
(8)
MITSUBISHI ELECTRIC
(15)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(18)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(3)
THERMOR
(0)
TOSHIBA
(15)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(2)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MOX201-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
X2AGN-09N8D6-OH/AGN-09N8D1-IH
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
WITO-09322.MH/WIT-09322.MH
WIT
|
WESTPOINT | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AITO-09322.MH/AIT-09322.MH
AIT
|
AIRCLASS | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
CU-NZ25YKE / CS-NZ25YKE
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-NZ25YKE / CS-NZ25YKE-1
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
RAS-25G3AVSG-ND/RAS-B25N4KVRG-ND
HAORI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
RAS-25G3AVSG-ND/RAS-B25G3KVSG-ND
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
RAS-25G3AVSG-ND/RAS-B25G3KVSGB-ND
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
MOX230-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
GFCAGBU-09HRFN8-PRO/GFCAGBU-09HRFN8-PRO
Extreme save R32
|
CONFORT AIR | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOD-09N8D6/MAG1-07N8
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOD-09N8D6/MAG1-09N8
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
ΝECUVO-09/ΝECUVI-09WFI
Neo Eco
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOX230-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)-CARBON
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOX2-09HFN8CD/MSAG-09HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MCX2-09HFN8CD/MCAG-09HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
NPVO-09/NPVI-09WFI
Neo Plus
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
WIMO-09326.MH / WIM-09326.MH
WIM 326
|
WESTPOINT | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
RAS-35G3AVSG-ND/RAS-B35G3KVSG-ND
SHORAI
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 5.10 | 4.57 | -25° | 3.50 | 3.60 | |
|
RAS-35G3AVSG-ND/RAS-B35G3KVSGB-ND
SHORAI
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 5.10 | 4.57 | -25° | 3.50 | 3.60 | |
|
RXTP25A / FTXTP25N
RXTP
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 4.95 | 4.95 | -30° | 2.50 | 2.50 | |
|
RXTP25A / FTXTP25A
RXTP
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 4.95 | 4.99 | -30° | 2.50 | 2.50 | |
|
CU-NZ35YKE / CS-NZ35YKE
2023
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
CU-NZ35YKE / CS-NZ35YKE-1
2024
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
RXTP35A / FTXTP35N
RXTP
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 4.85 | 4.55 | -30° | 3.50 | 3.00 | |
|
RXTP35A / FTXTP35A
RXTP
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 4.85 | 4.55 | -30° | 3.50 | 3.00 | |
|
CL8100i 65 E / CL8100i-W 65 E
Climate 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.75 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HE
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HET
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HES
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HER
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CU-2Z50ABEC/CS-HZ25ZKE/CS-HZ25ZKE
2024
|
PANASONIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.60 | 4.71 | -25° | 5.30 | 5.20 | |
|
MUZ-FH25VEHZ/MSZ-FH25VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 4.90 | 5.52 | -25° | 2.50 | 3.20 | |
|
CL9100i 85 E / CL9100i-W 85 E
Climate 9100i
|
BOSCH | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 5.37 | -25° | 3.50 | 4.00 | |
|
RXTM30A / FTXTM30S
RXTM
|
DAIKIN | Wall mounted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.65 | 5.20 | 5.20 | -30° | 3.00 | 3.00 | |
|
CU-HZ35XKE / CS-HZ35XKE
2022
|
PANASONIC | Wall mounted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.30 | 5.00 | -25° | 3.50 | 4.00 | |
|
CU-Z25UFEA-1 / CS-Z25UFEAW-1
2018
|
PANASONIC | Console | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.70 | 4.59 | -25° | 2.50 | 3.00 | |
|
CU-Z25CFEA-1 / CS-Z25CFEAW-1
2025
|
PANASONIC | Console | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.70 | 4.59 | -25° | 2.50 | 3.00 | |
|
RXTM30A / FTXTM30A
RXTM
|
DAIKIN | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.65 | 5.35 | 5.30 | -30° | 3.00 | 3.00 | |
|
ARXTM30A / ATXTM30A
ARXTM
|
DAIKIN | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.65 | 5.35 | 5.30 | -30° | 3.00 | 3.00 | |
|
CU-HZ25XKE / CS-HZ25XKE
2022
|
PANASONIC | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.30 | 5.61 | -25° | 2.50 | 3.00 | |
|
CU-HZ25XKE-5 / CS-HZ25XKE-5
2022
|
PANASONIC | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.30 | 5.61 | -25° | 2.50 | 3.00 | |
|
RAV-GP1101AT-E/RAV-HM1101CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.58 | 4.75 | 4.71 | -27° | 10.00 | 9.20 | |
|
MUZ-FH35VEHZ/MSZ-FH35VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.90 | 4.80 | 5.00 | -25° | 3.50 | 4.00 |