Filters · 2 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(6)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(11)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(10)
Fujitsu Atlantic
(0)
GENERAL
(10)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(5)
IVT
(0)
Inventor
(2)
KAYSUN
(0)
LG
(0)
MIDEA
(10)
MITSUBISHI ELECTRIC
(19)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(21)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(19)
THERMOR
(0)
TOSHIBA
(24)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(2)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-25E2AVG-ND/RAS-B25E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.45 | 4.27 | -25° | 2.50 | 2.80 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MUFZ-KW25VGHZ2/MFZ-KW25VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
AC035BXAPKG/AC035BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.04 | -25° | 3.50 | 2.50 | |
|
RAS-2HVRC3 / RCI-2.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.08 | 4.23 | -25° | 5.00 | 5.00 | |
|
MFZ-KW25VG/MUFZ-KW25VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
X2AGN-12N8D6-OH/AGN-12N8D1-IH
Xtreme Heat R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
MOX201-12HFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
AITO-12322.MH/AIT-12322.MH
AIT
|
AIRCLASS | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
MOX201-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
X2AGN-09N8D6-OH/AGN-09N8D1-IH
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
WITO-09322.MH/WIT-09322.MH
WIT
|
WESTPOINT | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AITO-09322.MH/AIT-09322.MH
AIT
|
AIRCLASS | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AOYG12KMCEN/ASYG12KMCEN
ASY**K
|
FUJITSU | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOHG12KMCEN/ASHG12KMCEN
ASH**K
|
GENERAL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOYG12KMCEN/ASEG12KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOHG12KMCEN/ASHG12KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
RAS-2.5HVRC3 / RPC-2.5FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.05 | 3.72 | -25° | 5.60 | 5.20 | |
|
RXTM30A / FVXTM30A
RXTM
|
DAIKIN | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.75 | 4.45 | -30° | 3.00 | 3.00 | |
|
RAS-2.5HVRC3 / RCI-2.5FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.53 | 4.18 | 4.12 | -25° | 5.60 | 5.20 | |
|
CU-NZ25YKE / CS-NZ25YKE
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-NZ25YKE / CS-NZ25YKE-1
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
MUZ-FT25VGHZ/MSZ-FT25VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.21 | -25° | 2.50 | 3.20 | |
|
MUZ-FT25VGHZ2/MSZ-FT25VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.21 | -25° | 2.50 | 3.20 | |
|
RAS-25G3AVSG-ND/RAS-B25N4KVRG-ND
HAORI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
RAS-25G3AVSG-ND/RAS-B25G3KVSG-ND
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
RAS-25G3AVSG-ND/RAS-B25G3KVSGB-ND
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
CU-2Z50ABEC/CS-Z25CKEW/CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.40 | 4.18 | -25° | 5.30 | 5.10 | |
|
MOX230-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
GFCAGBU-09HRFN8-PRO/GFCAGBU-09HRFN8-PRO
Extreme save R32
|
CONFORT AIR | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOD-09N8D6/MAG1-07N8
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOD-09N8D6/MAG1-09N8
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
ΝECUVO-09/ΝECUVI-09WFI
Neo Eco
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOX230-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)-CARBON
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOX2-09HFN8CD/MSAG-09HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MCX2-09HFN8CD/MCAG-09HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
NPVO-09/NPVI-09WFI
Neo Plus
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
WIMO-09326.MH / WIM-09326.MH
WIM 326
|
WESTPOINT | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 |