Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(5)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(12)
THERMOR
(0)
TOSHIBA
(11)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUHZ-SHW230YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.81 | 3.51 | 3.47 | -25° | 19.00 | 23.00 | |
|
MXZ-4F83VFHZ2/MSZ-AY42VG/MSZ-AY42VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.14 | 4.00 | 3.28 | -25° | 8.30 | 9.00 | |
|
MXZ-4F83VFHZ3/MSZ-AY42VGK(P)2/MSZ-AY42VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.14 | 4.00 | 3.28 | -25° | 8.30 | 9.00 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
AC140BXAPNG / AC140BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.41 | -25° | 13.40 | 9.20 | |
|
AC120BXAPNG / AC120BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.77 | -25° | 12.10 | 9.20 | |
|
RAV-GP1401AT-E1/RAV-HM1401BTP-E
SDI
|
TOSHIBA | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.28 | 3.86 | -27° | 12.50 | 9.60 | |
|
AC140BXAPNG / AC140BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.70 | 3.97 | -25° | 13.40 | 9.50 | |
|
AC140BXAPNG / AC140BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.63 | -25° | 13.40 | 9.50 | |
|
AC100BXAPKG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AC100BXAPNG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AC120BXAPNG / AC120BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.70 | 4.13 | -25° | 12.10 | 9.50 | |
|
RAV-GP1401AT-E1/RAV-HM1401CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.99 | 4.73 | 3.90 | -27° | 12.50 | 9.60 | |
|
RAV-GP1101AT-E/RAV-HM1101KRTP-E
SDI
|
TOSHIBA | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.42 | 3.58 | -27° | 10.00 | 9.20 | |
|
RAV-GP1101AT-E/RAV-HM1101BTP-E
SDI
|
TOSHIBA | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.19 | 4.30 | 4.10 | -27° | 10.00 | 9.20 | |
|
AC120BXAPNG / AC120BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 4.00 | -25° | 12.10 | 9.50 | |
|
AC100BXAPKG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC100BXAPNG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
RAV-GP1101AT-E/RAV-HM1101CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.58 | 4.75 | 4.71 | -27° | 10.00 | 9.20 | |
|
RAV-GP1401AT-E1/RAV-HM1401FT-E
SDI
|
TOSHIBA | Floor standing | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.49 | 4.38 | 3.00 | -27° | 12.30 | 9.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401UTP-E
SDI
|
TOSHIBA | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 4.74 | 4.36 | -27° | 12.50 | 9.60 | |
|
AC100BXAPKG/AC100BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.44 | -25° | 10.00 | 8.50 | |
|
AC100BXAPNG/AC100BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.44 | -25° | 10.00 | 8.50 | |
|
RAV-GP1101AT-E/RAV-HM1101FT-E
SDI
|
TOSHIBA | Floor standing | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.40 | 4.06 | -27° | 10.00 | 9.20 | |
|
RAV-GP1101AT-E/RAV-HM1101UTP-E
SDI
|
TOSHIBA | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 4.76 | 4.79 | -27° | 10.00 | 9.20 | |
|
RAV-GP1401AT-E1/RAV-HM1401UT-E
SDI
|
TOSHIBA | Cassette | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.87 | 5.00 | 4.61 | -27° | 12.50 | 9.60 | |
|
RAV-GP1101AT-E/RAV-HM1101UT-E
SDI
|
TOSHIBA | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.03 | 5.14 | -27° | 10.00 | 9.20 |