Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(10)
BRYANT
(0)
Buderus
(4)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(11)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(12)
Fujitsu Atlantic
(0)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(14)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(0)
MIDEA
(33)
MITSUBISHI ELECTRIC
(38)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(27)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(37)
THERMOR
(0)
TOSHIBA
(43)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MXZ-4F83VFHZ2/MSZ-AY42VG/MSZ-AY42VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.14 | 4.00 | 3.28 | -25° | 8.30 | 9.00 | |
|
MXZ-4F83VFHZ3/MSZ-AY42VGK(P)2/MSZ-AY42VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.14 | 4.00 | 3.28 | -25° | 8.30 | 9.00 | |
|
CU-CZ35WKE / CS-CZ35WKE
2020
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.08 | -25° | 3.50 | 3.60 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
RAS-35E2AVG-ND/RAS-B35E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.50 | 3.89 | -25° | 3.50 | 3.40 | |
|
RAS-35G3AVSG-ND/RAS-B35G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.77 | -25° | 3.50 | 3.60 | |
|
MUFZ-KW35VGHZ2/MFZ-KW35VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
AC026BXAPKG/AC026BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.33 | -25° | 2.60 | 2.00 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
MFZ-KW35VG/MUFZ-KW35VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
RAV-GP561ATW-E/RAV-HM561FT-E
SDI
|
TOSHIBA | Floor standing | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.21 | 3.39 | -27° | 5.00 | 3.80 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
AC071BXAPKG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
AC071BXAPNG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
RAS-3HVRC3 / RPI-3.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.92 | 3.84 | -25° | 7.10 | 6.00 | |
|
RAV-GP561ATW-E/RAV-HM561KRTP-E
SDI
|
TOSHIBA | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.84 | 4.19 | 4.03 | -27° | 5.00 | 3.80 | |
|
AC100BXAPKG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AC100BXAPNG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
MUFZ-KW25VGHZ2/MFZ-KW25VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
AC035BXAPKG/AC035BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.04 | -25° | 3.50 | 2.50 | |
|
RAS-2HVRC3 / RCI-2.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.08 | 4.23 | -25° | 5.00 | 5.00 | |
|
MFZ-KW25VG/MUFZ-KW25VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
MUZ-FT50VGHZ/MSZ-FT50VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.30 | 3.85 | -25° | 5.00 | 5.00 | |
|
MUZ-FT50VGHZ2/MSZ-FT50VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.30 | 3.85 | -25° | 5.00 | 5.00 | |
|
MUZ-FH50VEHZ/MSZ-FH50VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 4.05 | -25° | 5.00 | 6.00 | |
|
RAS-3HVRC3 / RPC-3.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.09 | 3.73 | -25° | 7.10 | 6.00 | |
|
RAV-GP801ATW-E/RAV-HM801KRTP-E
SDI
|
TOSHIBA | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.56 | 4.16 | 3.56 | -27° | 7.10 | 5.10 | |
|
MFZ-KW60VG/MUFZ-KW60VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MUFZ-KW60VGHZ2/MFZ-KW60VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MOX230-12HFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
GFCAGBU-12HRFN8-PRO/GFCAGBU-12HRFN8-PRO
Extreme save R32
|
CONFORT AIR | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
X2AGN-12N8D6-OH/AGN-12N8D1-IH
Xtreme Heat R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
MOX201-12HFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
MOD-12N8D6/MAG1-12N8
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
ΝECUVO-12/ΝECUVI-12WFI
Neo Eco
|
Inventor | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIM-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
MOX230-12HFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW-CARBON
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
MOX2-12HFN8CD/MSAG-12HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
MCX2-12HFN8CD/MCAG-12HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 |