Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(7)
ATLANTIC
(2)
AUX
(10)
BOSCH
(9)
BRYANT
(0)
Buderus
(1)
CARRIER
(27)
CIAT
(14)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(322)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(31)
FUJITSU
(84)
Fujitsu Atlantic
(43)
GENERAL
(42)
GREE
(10)
GSS
(0)
HAIER
(140)
HEC
(0)
HEIWA
(0)
HISENSE
(40)
HITACHI
(63)
IVT
(0)
Inventor
(32)
KAYSUN
(32)
LG
(70)
MIDEA
(163)
MITSUBISHI ELECTRIC
(149)
Mitsubishi Heavy Industries
(299)
NORD
(4)
Nobu
(0)
PANASONIC
(67)
PITSOS
(0)
RIELLO
(15)
Rotenso
(8)
SAMSUNG
(41)
THERMOR
(0)
TOSHIBA
(73)
Viessmann
(6)
Vulcano
(1)
WESTPOINT
(0)
XTRON
(0)
YORK
(14)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOX630U-48HFN8-R(GA)/MFM-48HRFN8-QRD0W V1
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.45 | -10° | 14.10 | 11.40 | |
|
MOX630U-55HFN8-RRD0W(GA)/MFM-55HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MO-55N8-R-1/MFM-55N8
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-55HFN8-R(GA)/MFM-55HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-55HFN8-R OUT V1/MFM-55HRFN8-Q IN V1
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
KUE-160 DTR14/KPV-160 DR14
Zen
|
KAYSUN | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-55HFN8-RRD0W(GA)-GR/MFM-55HRFN8-QRD0W-GR
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
AD125S2SM3FA/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
U-200PZH4E8 / S-200PE4E
2024
|
PANASONIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.02 | 3.85 | 3.55 | 19.00 | 14.50 | ||
|
RAS-4HVNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.17 | 3.83 | 2.87 | -20° | 10.00 | 7.40 | |
|
RZA200D
RZA
|
DAIKIN | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.84 | 19.00 | 11.20 | |||
|
FDC125VNX/FDTC60VH/FDTC60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.01 | 3.41 | 12.50 | 11.40 | ||
|
42QZL060D8S/38QUS060D8TX
Ceiling suspended
|
CARRIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
42QZL048D8S/38QUS048D8TX
Ceiling suspended
|
CARRIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.36 | 3.95 | 3.33 | -10° | 23.50 | 12.30 | |
|
AD140S2SM3FA/1U140S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.64 | 3.96 | 3.13 | 13.40 | 8.50 | ||
|
AD140S2SM8FA/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 3.93 | 3.05 | 13.40 | 8.50 | ||
|
AD140S2SM8FA(H)/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 3.93 | 3.05 | 13.40 | 8.50 | ||
|
AD140S2SM9FA(H)/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 3.93 | 3.05 | 13.40 | 8.50 | ||
|
PUZ-M250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.03 | 4.16 | 3.19 | -20° | 22.00 | 20.20 | |
|
FDC140VSX-W/FDUM140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.88 | 2.63 | 14.00 | 15.50 | ||
|
FDC140VSX-W/FDU140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.88 | 2.63 | 14.00 | 15.50 | ||
|
U5MRSL32(4)-36/AR5VI-18WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.20 | -10° | 10.50 | 8.30 | |
|
AUC175UR4RKC8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 2.97 | -10° | 16.00 | 10.00 | |
|
RAV-GM1402AT8W-E/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 3.84 | 3.71 | -15° | 12.10 | 8.40 | |
|
MOD30U-42HFN8-QRD0W(GA)/MCD1-42HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
MOD30U-42HFN8-Q(GA)/MCD1-42HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
KUE-125 DVR13/KCIS-125 DR13
Zen
|
KAYSUN | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
MO-42N8-Q/MCD-42NX
Cassette R32
|
MIDEA | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
KUE-125 DVR13/KCIS-125 DR14
Zen
|
KAYSUN | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
T120Xi R16/UO120Xo R14
Tenji
|
Rotenso | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
MOD30U-42HFN8-Q(GA)/MCD2-42HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
MOD30U-42HFN8-Q(H)/MCD2-42HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
AOYG45LATT/ABYG45LRTA
AOYG**L
|
FUJITSU | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
AOHG45LATT/ABHG45LRTA
AOHG**L
|
GENERAL | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
AOYG45LATT/ABYG45LRTA
AOYG**L
|
Fujitsu Atlantic | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
U-140PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
U-140PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
MOE30U-48HFN8-RRD0W(GA)/MCD1-48HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
MOE30U-48HFN8-R(GA)/MCD1-48HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
MO-48N8-R/MCD-48NX
Cassette R32
|
MIDEA | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
KUE-140 DTR13/KCIS-140 DR14
Zen
|
KAYSUN | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
U7RT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
MOE30U-48HFN8-RRD0W(GA)-GR/MCD1-48HRFNX-QRD0W(GA)-GR
Cassette R32
|
MIDEA | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
FDC125VSX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VSX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
42HK42VDS8C*/38HU42VDS8C*
Cassette
|
CIAT | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.59 | 12.10 | 9.50 | ||
|
42QTD042D8S*/38QUS042D8S*
Cassette
|
CARRIER | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.59 | 12.10 | 9.50 | ||
|
KC212HIDS8*/AIC212HIDS8*
Cassette
|
RIELLO | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.59 | 12.10 | 9.50 |