Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(7)
ATLANTIC
(2)
AUX
(10)
BOSCH
(9)
BRYANT
(0)
Buderus
(1)
CARRIER
(27)
CIAT
(14)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(322)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(31)
FUJITSU
(84)
Fujitsu Atlantic
(43)
GENERAL
(42)
GREE
(10)
GSS
(0)
HAIER
(140)
HEC
(0)
HEIWA
(0)
HISENSE
(40)
HITACHI
(63)
IVT
(0)
Inventor
(32)
KAYSUN
(32)
LG
(70)
MIDEA
(163)
MITSUBISHI ELECTRIC
(149)
Mitsubishi Heavy Industries
(299)
NORD
(4)
Nobu
(0)
PANASONIC
(67)
PITSOS
(0)
RIELLO
(15)
Rotenso
(8)
SAMSUNG
(41)
THERMOR
(0)
TOSHIBA
(73)
Viessmann
(6)
Vulcano
(1)
WESTPOINT
(0)
XTRON
(0)
YORK
(14)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-5HRC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.37 | 4.25 | 3.98 | -20° | 11.90 | 11.93 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
MOX630U-55HFN8-RRD0W(GA)/MTJ-55HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-R(GA)/MTJ-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MO-55N8-R-1/MTJ-55NX
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-RRD0W/MTJI-55HWFNX
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
KUE-160 DTR14/KPD-160 DR15
Zen
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-RRD0W(GA)-GR/MTJ-55HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
N160Xi R15/UO160Xo R15
Nevo
|
Rotenso | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
42QSV060D8S/38QUS060D8TX
Duct R32
|
CARRIER | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-R(H)/MTJ-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-R OUT V1/MTJ-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.28 | 4.11 | 3.50 | -10° | 20.00 | 11.40 | |
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.39 | 4.10 | 22.00 | 12.10 | |||
|
PUZ-ZM250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.13 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
FDC100VSA-W/SRK100ZR-W
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/SRK100ZR-WF
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/SRK100ZR-WF
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
AOYG36LATT/AUYG36LRLA
AUY**L
|
FUJITSU | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.38 | -15° | 10.00 | 10.00 | |
|
FDC140VNX-W/FDE140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.17 | 2.90 | 14.00 | 13.00 | ||
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
YUKF36BYEEBMO-1/YFKF36BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
RAV-GM1602AT8W-E/RAV-HM1601CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.22 | 3.41 | -15° | 14.00 | 8.00 | |
|
AD140S2SM3FA/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.06 | 3.73 | 13.40 | 11.00 | ||
|
ADH140H1ERG/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.07 | 3.72 | 13.60 | 10.00 | ||
|
AD140S2SM3FA/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
PUZ-ZM140YDA2/PLA-M140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.14 | 3.50 | -20° | 13.40 | 10.60 | |
|
FDC100VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.13 | 4.08 | -15° | 10.00 | 6.40 | |
|
FDC100VNP-W/FDUM100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.13 | 4.08 | -15° | 10.00 | 6.40 | |
|
PUZ-M140YKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140YKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-ZM140YDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RAS-4HNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.96 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAV-GP1601AT8-E/RAV-HM1601FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.98 | 3.31 | -20° | 14.00 | 12.00 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
RAV-GM1601ATP-E/RAV-HM1601UTP-E
DI
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
FDC125VNA/FDT125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.38 | 3.74 | 12.50 | 9.80 | ||
|
FDC125VSX/FDE60VH/FDE60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.65 | 4.07 | 3.78 | 12.50 | 14.00 | ||
|
AC140RXADKG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.16 | -20° | 13.40 | 8.40 |