Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(7)
ATLANTIC
(2)
AUX
(4)
BOSCH
(14)
BRYANT
(0)
Buderus
(4)
CARRIER
(19)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(174)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(15)
Fujitsu Atlantic
(5)
GENERAL
(10)
GREE
(8)
GSS
(0)
HAIER
(40)
HEC
(0)
HEIWA
(1)
HISENSE
(61)
HITACHI
(31)
IVT
(3)
Inventor
(11)
KAYSUN
(0)
LG
(23)
MIDEA
(56)
MITSUBISHI ELECTRIC
(82)
Mitsubishi Heavy Industries
(97)
NORD
(5)
Nobu
(0)
PANASONIC
(50)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(16)
THERMOR
(0)
TOSHIBA
(58)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(4)
YORK
(0)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC71VNP-W/SRK71ZR-W
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 4.55 | 3.78 | -15° | 7.10 | 5.70 | |
|
CU-TZ50WKE / CS-TZ50WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50ZKE / CS-TZ50ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50CKE / CS-TZ50CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
FM48AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM49AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM48AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM49AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
SRC50ZS-W/SRK50ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
SRC50ZS-W/SRK50ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
SRC50ZS-W/SRK50ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
SRC50ZS-W/SRK50ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
AOEH36KMTB/ASEH36KMTB
ASE**K
|
FUJITSU | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOHH36KMTB/ASHH36KMTB
ASY**K
|
GENERAL | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
FUJITSU | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
ROH36KMTB/RSH36KMTB
RS**K
|
FUJI ELECTRIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
MOX430-18AFN8-QRD0GW/MSAGCU-18HRFNX-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
RAS-18J2AVSG-E1/RAS-B18J2FVG-E
Console
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 2.93 | -15° | 5.00 | 4.00 | |
|
MUZ-HR60VF/MSZ-HR60VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.50 | 3.76 | -10° | 6.10 | 4.60 | |
|
MUZ-HR60VF2/MSZ-HR60VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.50 | 3.76 | -10° | 6.10 | 4.60 | |
|
PUZ-SM100VKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
RAC-DJ50WHAE / RAK-DJ50RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.50 | 3.71 | -15° | 5.00 | 4.35 | |
|
RAS-18P2AVSG-E/RAS-B18J2FVG-E1
Console
|
TOSHIBA | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.00 | -20° | 5.00 | 4.00 | |
|
MUZ-EF50VE/MSZ-EF50VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.50 | 3.71 | -15° | 5.00 | 4.20 | |
|
RXJ50A / FTXJ50AB
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A / FTXJ50AS
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A / FTXJ50AW
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXA50B8 / FTXA50CS
RXA
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | -10° | 5.00 | 4.00 | ||
|
RXA50B8 / FTXA50CB
RXA
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | -10° | 5.00 | 4.00 | ||
|
RXA50B8 / FTXA50CW
RXA
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | -10° | 5.00 | 4.00 | ||
|
RXJ50A9 / FTXJ50AS
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A9 / FTXJ50AB
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A9 / FTXJ50AW
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXA50B8 / FTXA50CW
RXA
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXA50B8 / FTXA50CB
RXA
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXA50B8 / FTXA50CS
RXA
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A9 / FTXJ50AW
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A9 / FTXJ50AB
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A9 / FTXJ50AS
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 |