Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(52)
ATLANTIC
(17)
AUX
(91)
BOSCH
(62)
BRYANT
(2)
Buderus
(18)
CARRIER
(93)
CIAT
(31)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(2)
DAIKIN
(676)
DE DIETRICH
(8)
EQUATION
(3)
FUJI ELECTRIC
(93)
FUJITSU
(252)
Fujitsu Atlantic
(118)
GENERAL
(120)
GREE
(62)
GSS
(2)
HAIER
(370)
HEC
(0)
HEIWA
(3)
HISENSE
(208)
HITACHI
(132)
IVT
(4)
Inventor
(94)
KAYSUN
(56)
LG
(232)
MIDEA
(506)
MITSUBISHI ELECTRIC
(467)
Mitsubishi Heavy Industries
(365)
NORD
(30)
Nobu
(4)
PANASONIC
(192)
PITSOS
(2)
RIELLO
(32)
Rotenso
(8)
SAMSUNG
(120)
THERMOR
(21)
TOSHIBA
(222)
Viessmann
(16)
Vulcano
(10)
WESTPOINT
(12)
XTRON
(2)
YORK
(29)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AG2Eco-24N8D0-O(A)/AG2Eco-24NXD0-I(A)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
MOX401-24HFN8/LT/MSAGWDU-24HRFN8
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Lite-24N8D0-O/AG2Lite -24NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Dura-24N8D0-O/AG2Dura-24NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
MOX401-24HFN8/LT/MSAGGDU-24HRFN8
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Eco-24N8D0-O(R)/AG2Eco-24NXD0-I(R)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Line-24N8D0-O(A)/AG2Line-24NXD0-I(A)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
MOX401-24HFN8/MSAGDU-24HRFN8/WR
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG1-24N8D0-O(B)/AG1-24NXD0-I(B)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
MOX4M01-24HFN8-QRD0GW/MSAGMDU-24HRFN8-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Pro-24N8D0-O/AG2Pro-24NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
X4BP-24N8D0-O/AGBP-24NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Dura-24N8D0-O(R)/AG2Dura-24NXD0-I(R)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Eco-24N8D0-O(B)/AG2Eco-24NXD0-I(B)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG1-24N8D0-O/AG1-24NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
MOX401-24HFN8/MSAGDU-24HRFN8/GR
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG1Pro-24N8D0-O(B)/AG1Pro-24NXD0-I(B)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Line-24N8D0-O/AG2Line-24NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Eco-24N8D0-O/AG2Eco-24NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
MOX401-24HFN8/LT/MSAGXDU-24HRFN8
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG1Pro-24N8D0-O(R)/AG1Pro-24NXD0-I(R)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
MOX401-24HFN8-QRD0GW/MSAGDU-24HRFN8-QRD0GW-HIWF
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG1-24N8D0-O(R)/AG1-24NXD0-I(R)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Pro-24N8D0-O(U)/AG2Pro-24NXD0-I(U)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AG2Eco-24N8D0-O(U)/AG2Eco-24NXD0-I(U)
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
X4-24N8D0-O/AGU-24NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
MOM-24N8D0-1/MAG2-24N8-2
Extreme save R32
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -10° | 7.00 | 4.90 | |
|
AC 024 DB.UI/1U 024 DC.UE
Ceiling floor- Monosplit
|
ATLANTIC | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.26 | -10° | 7.10 | 5.00 | |
|
AB71S2SA1FA/1U71S2SR2FA
1-way cassette-Monosplit
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.72 | -10° | 6.90 | 5.00 | |
|
AB71S2SA1FA(H)/1U71S2SR2FA
1-way cassette-Monosplit
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.72 | -10° | 6.90 | 5.00 | |
|
AB71S2SG1FA/1U71S2SR2FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.72 | -10° | 7.10 | 5.00 | |
|
NAGANO CASSETTE IK70-F88-NG / E1U70LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.72 | -10° | 7.10 | 5.00 | |
|
AB71S2SG1FA(H)/1U71S2SR2FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.72 | -10° | 7.10 | 5.00 | |
|
AB71S2SR1FA(H)/1U71S2SR3FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.72 | -10° | 7.10 | 5.00 | |
|
YDAM-070R-09M22/CDHM-070N-09M22
OASIS
|
AIRWELL | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.72 | -10° | 7.10 | 5.00 | |
|
RPIH-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.72 | 2.95 | -10° | 17.10 | 11.00 | |
|
5MWXM68A9 / FTXM42A / FTXM25A
5MWXM
|
DAIKIN | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.85 | 3.24 | -15° | 6.70 | 4.30 | |
|
UUA1 UL0 / CM18F N10
UU
|
LG | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
UUA1 UL0 / CM18F N11
UU
|
LG | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
UU250W U80A0 / UB250 N80
UU
|
LG | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.83 | 3.79 | 23.00 | 17.60 | ||
|
PUZ-ZM60VHA2/SLZ-M60FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/SLZ-M60FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.10 | -20° | 6.10 | 4.40 | |
|
RXM50A9 / FDXM50F9
RXM
|
DAIKIN | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -10° | 5.00 | 4.00 | |
|
RZASG140MY1 / FBA140A
RZASG
|
DAIKIN | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.85 | 3.98 | 13.40 | 7.80 | ||
|
UUB1 U20 / MJ18PC NSK
UU
|
LG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -10° | 5.00 | 3.90 | |
|
UUB1 U20 / MJ18PC NSK0
UU
|
LG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -10° | 5.00 | 3.90 | |
|
ASW-H18E3G4/JAR3DI-C0 / ASW-H18E3G4/JAR3DI-C0
J SERIES
|
AUX | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
ASW-H18E3G4/QCR3DI-C0 / ASW-H18E3G4/QCR3DI-C0
Q SERIES
|
AUX | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.10 | -10° | 5.30 | 3.90 | |
|
ASW-H18E3H4/JAR3DI-C0 / ASW-H18E3H4/JAR3DI-C0
J SERIES
|
AUX | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
NOBO-18/NOBI-18WFI
Nobu
|
Nobu | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 |