Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(52)
ATLANTIC
(17)
AUX
(91)
BOSCH
(62)
BRYANT
(2)
Buderus
(18)
CARRIER
(93)
CIAT
(31)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(2)
DAIKIN
(676)
DE DIETRICH
(8)
EQUATION
(3)
FUJI ELECTRIC
(93)
FUJITSU
(252)
Fujitsu Atlantic
(118)
GENERAL
(120)
GREE
(62)
GSS
(2)
HAIER
(370)
HEC
(0)
HEIWA
(3)
HISENSE
(208)
HITACHI
(132)
IVT
(4)
Inventor
(94)
KAYSUN
(56)
LG
(232)
MIDEA
(506)
MITSUBISHI ELECTRIC
(467)
Mitsubishi Heavy Industries
(365)
NORD
(30)
Nobu
(4)
PANASONIC
(192)
PITSOS
(2)
RIELLO
(32)
Rotenso
(8)
SAMSUNG
(120)
THERMOR
(21)
TOSHIBA
(222)
Viessmann
(16)
Vulcano
(10)
WESTPOINT
(12)
XTRON
(2)
YORK
(29)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL5000L 105 E-3 / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-RRD0W(GA)/MTI-36HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MO-36N8-R/MTI-36HNX
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
KUE-105 DTR13/KPD-105 DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-RRD0W(GA)/MTJ-36HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-R(GA)/MTJ-36HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
MO-36N8-R/MTJ-36NX
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-RRD0W(GA)-GR/MTI-36HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
KUE-105 DTR13/KPD-105 DR15
Duct R32
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
YUKF36BYOEBMO-1/YEKF36BXOEBM-R1
Grande Duct R32
|
YORK | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
DDMD-100N-09M25/YDAX-100H-09T35**
DDMD
|
AIRWELL | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
42QSV036D8S*/38QUS036D8T*
Ducted
|
CARRIER | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
Vitoclima100-SPROIDHAA100MFP105/Vitoclima100-SPROOFAA100TFP105
Ducted
|
Viessmann | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-R(H)/MTJ-36HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
CL5001L 105 E-3 / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOHG18KBTA3/ASHG07KMCC/ASHG12KMCC
AOH**K Multi
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
ROG18KBTA3/RSG07KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOEG18KBCA3/ASEH07KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
MXZ-5F102VF2/MSZ-AY42VG/MSZ-AY50VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
MXZ-5F102VF3/MSZ-AY42VGK(P)2/MSZ-AY50VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
RXM50A8 / FBA50A9
RXM
|
DAIKIN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.02 | 3.71 | -15° | 5.00 | 4.40 | |
|
SUZ-M60VA/SFZ-M60VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/SFZ-M60VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA/PEAD-M60JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA/PEAD-M60JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/PEAD-M60JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/PEAD-M60JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -10° | 6.10 | 4.60 | |
|
5MXM90A9 / FTXM20R / FTXM71R
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.26 | 3.69 | -15° | 8.00 | 4.50 | |
|
5MXM90A9 / FTXM20A / FTXM71A
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.26 | 3.69 | -15° | 8.00 | 4.50 | |
|
AOEG45KBTB/ARXH45KMTAP
ARX**K
|
FUJITSU | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ARXH45KMTAP
ARX**K
|
FUJITSU | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOHG45KBTB/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXH45KMTAP
ARX**K
|
FUJITSU | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXH45KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXH45KMTAP
ARX**K
|
FUJITSU | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXH45KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
FDC100VNA-W/FDUM50VH/FDUM50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.00 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDUM50VH/FDUM50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.00 | 3.68 | -20° | 10.00 | 8.50 | |
|
5MXM90A9 / CTXM15R / FTXM71R
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.28 | 3.67 | -15° | 8.00 | 4.50 | |
|
5MXM90A9 / CTXM15A / FTXM71A
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.28 | 3.67 | -15° | 8.00 | 4.50 | |
|
AOHG24KLTA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLTA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLCA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOHG24KLCA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
FUJITSU | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOEG24KLCA/ASEG24KLCA
ASE**K
|
FUJITSU | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 |