Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(4)
ATLANTIC
(0)
AUX
(4)
BOSCH
(7)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(233)
DE DIETRICH
(0)
EQUATION
(1)
FUJI ELECTRIC
(15)
FUJITSU
(36)
Fujitsu Atlantic
(15)
GENERAL
(18)
GREE
(24)
GSS
(0)
HAIER
(30)
HEC
(0)
HEIWA
(0)
HISENSE
(51)
HITACHI
(39)
IVT
(1)
Inventor
(11)
KAYSUN
(6)
LG
(46)
MIDEA
(49)
MITSUBISHI ELECTRIC
(118)
Mitsubishi Heavy Industries
(168)
NORD
(5)
Nobu
(0)
PANASONIC
(46)
PITSOS
(0)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(31)
THERMOR
(0)
TOSHIBA
(69)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(4)
XTRON
(0)
YORK
(1)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ABH105H1ERG(H)/1U105S2SS1FB
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 6.00 | |
|
FDC280VSA-W/FDT140VH/FDT140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.22 | 3.35 | 27.00 | 17.80 | ||
|
ABH105H1ERG(H)/1U105S2SS2FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
M4OA-27HFN8-Q(HRU)/MCA4U-09HRFNX-QRD1W(GA)+MCA4U-18HRFNX-QRD1W(GA)
M4OA-27HFN8-Q(HRU)
|
MIDEA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 7.90 | 6.30 | |
|
RAV-GV1601ATP-E1/RAV-HM1601UTP-E
DIC 1ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.46 | -15° | 13.00 | 8.00 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
RAV-GM1401ATP-E1/RAV-HM1401UTP-E
DI
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
AS71S2SF1FA-BH/1U71S2ST1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.26 | -10° | 7.00 | 5.60 | |
|
AS71S2SF1FA-WH/1U71S2ST1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.26 | -10° | 7.00 | 5.60 | |
|
AB71S2SR1FA(H)/1U71S2SR2FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.72 | -10° | 7.10 | 5.00 | |
|
FDC200VSA-W/SRK100ZR-W/SRK100ZR-W
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.36 | 3.26 | 20.00 | 12.50 | ||
|
FDC125VNA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC125VSA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
AZAS140MY1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
AZAS140MV1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
RCI-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -15° | 8.70 | 7.20 | |
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
FDC140VNA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
UUD1 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD3 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZTNW60GALA1
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
FDC140VNA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC140VSA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
4MXM80A9 / FTXM35R / FTXM42R
4MXM
|
DAIKIN | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.23 | 3.56 | -15° | 7.70 | 4.27 | |
|
4MXM80A9 / FTXM35A / FTXM42A
4MXM
|
DAIKIN | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.23 | 3.56 | -15° | 7.70 | 4.27 | |
|
FDC125VNP-W/FDT125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.37 | 4.27 | 3.78 | 12.10 | 8.00 | ||
|
U-71PZ3E5A / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.40 | 4.23 | -15° | 7.10 | 5.20 | |
|
AZAS140MV / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
AZAS140MY / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
AS71S2SF1FA-MW3/1U71S2ST1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
AS71S2SF1FA-WH/1U71WEGFRA
RAC Flexis
|
HAIER | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
Virtus-24K-IN/Virtus-24K-OUT
Tundra Plus
|
EQUATION | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
CU-Z71XKE / CS-Z71XKEW
2021
|
PANASONIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.69 | -15° | 7.10 | 5.50 | |
|
M4OA-27HFN8-Q(HRU)/MSAGAU-09HRFN8-QRD1GW+MSAGCU-18HRFNX-QRD0GW
M4OA-27HFN8-Q(HRU)
|
MIDEA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.71 | -10° | 7.90 | 6.20 | |
|
RAV-GM1402AT8W-E/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.20 | 3.79 | -15° | 12.10 | 8.00 | |
|
RAV-GM1101ATP-E/RAV-HM1101UTP-E
DI
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RAV-GM1101AT8P-E/RAV-HM1101UTP-E
DI 3ph
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
FDC71VNP-W/SRK71ZR-W
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 4.55 | 3.78 | -15° | 7.10 | 5.70 | |
|
FDC125VNP-W/FDE125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.95 | 4.21 | 3.67 | 12.10 | 7.90 | ||
|
5MXM90A9 / FTXM20R / FTXM71R
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.26 | 3.69 | -15° | 8.00 | 4.50 | |
|
5MXM90A9 / FTXM20A / FTXM71A
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.26 | 3.69 | -15° | 8.00 | 4.50 |