Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(26)
ATLANTIC
(8)
AUX
(28)
BOSCH
(30)
BRYANT
(1)
Buderus
(7)
CARRIER
(54)
CIAT
(21)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(441)
DE DIETRICH
(1)
EQUATION
(1)
FUJI ELECTRIC
(59)
FUJITSU
(159)
Fujitsu Atlantic
(76)
GENERAL
(76)
GREE
(33)
GSS
(0)
HAIER
(246)
HEC
(0)
HEIWA
(0)
HISENSE
(74)
HITACHI
(88)
IVT
(1)
Inventor
(62)
KAYSUN
(46)
LG
(113)
MIDEA
(320)
MITSUBISHI ELECTRIC
(326)
Mitsubishi Heavy Industries
(332)
NORD
(15)
Nobu
(1)
PANASONIC
(111)
PITSOS
(1)
RIELLO
(22)
Rotenso
(8)
SAMSUNG
(69)
THERMOR
(12)
TOSHIBA
(138)
Viessmann
(12)
Vulcano
(5)
WESTPOINT
(5)
XTRON
(0)
YORK
(22)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
EZ-24RD6H-O/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6-O/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6H-O/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
HDMC-070N-09M25/YDA*-070*-09M25
Harmonia
|
AIRWELL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4-24RD6/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4-24RD6/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4H-24RD6/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4H-24RD6/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
42QCE024D8SH/38QCE024D8SH
Wall mounted
|
CARRIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6-O-H/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
KAE-S 71 DR13/KAY-S 71 DR13
SUITE Silver
|
KAYSUN | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
AUC140UR4RKC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
AUC140UR4RKC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
RAM-Y70N4HAE / RAK-XJ35RHBE / RAK-XJ35RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 7.00 | 5.90 | |
|
U-100PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.93 | -15° | 10.00 | 10.00 | |
|
AC100RXADKG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.50 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.55 | -20° | 10.00 | 5.30 | |
|
SRC80ZR-W/SRK80ZR-W
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.96 | -15° | 8.00 | 7.10 | |
|
AUW105U6RN8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -10° | 10.00 | 8.00 | |
|
AOHH24KMTG/ASHH24KMTGL
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
AOEH24KMTG/ASEH24KMTGL
ASE**K
|
FUJITSU | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
FDC100VNA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
MOD30U-36HFN8-QRD0W(GA)/MUE-36HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-Q(GA)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-QRD0W(GA)/MUE-36HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-QRD0W(GA)/MUE-36HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
FDMX-100N-09M25/YDAX-100H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MO-36N8-Q/MUE-36NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
KUE-105 DVR13/KPC-105 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MO-36N8-Q/MUE-36NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-Q(H)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
PUZ-M200YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.94 | 4.20 | 3.30 | -20° | 19.00 | 15.50 | |
|
RAC-70NPD / RAK-70PPD
RAC-NPE(D)
|
HITACHI | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.41 | 3.81 | -15° | 7.00 | 6.40 | |
|
PUZ-ZM100VDA/PLA-M100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.30 | 4.17 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PLA-M100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.30 | 4.17 | -20° | 9.50 | 7.80 | |
|
RAV-GP1101AT8-E/RAV-HM1101BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.19 | 4.06 | -20° | 10.00 | 10.80 | |
|
RZA250D
RZA
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.10 | 22.00 | 12.10 | |||
|
U-250PZH4E8 + P‐VTVF250NC5‐PE
2025
|
PANASONIC | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-250PZH4E8 + P‐VTVF250PC5‐PE
2025
|
PANASONIC | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-71PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
RAS-4M27G3AVG-E/RAS-B16G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
RAS-4M27G3AVG-E/RAS-B16P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
RAV-GP1401AT8-E1/RAV-HM1401FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.02 | 3.00 | -20° | 12.50 | 11.80 | |
|
RAV-GM901ATP-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.42 | 12.10 | 6.00 |