Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(1)
HITACHI
(8)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(2)
MIDEA
(0)
MITSUBISHI ELECTRIC
(8)
Mitsubishi Heavy Industries
(27)
NORD
(0)
Nobu
(0)
PANASONIC
(21)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC250VSA/FDU250VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.82 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
FDC250VSA/FDU250VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.83 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
FDC250VSA-W/FDU250VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.54 | 3.75 | 25.00 | 14.20 | ||
|
FDC125VSX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.74 | 3.66 | 3.71 | 12.50 | 14.00 | ||
|
U-250PZH4E8 / S-250PE4E
2024
|
PANASONIC | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 3.83 | 3.55 | 22.00 | 15.00 | ||
|
UU250W U80A0 / UB250 N80
UU
|
LG | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.83 | 3.79 | 23.00 | 17.60 | ||
|
U-200PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.07 | 3.87 | 3.71 | -20° | 16.00 | 15.70 | |
|
UU200W U80A0 / UB200 N80
UU
|
LG | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 3.83 | 4.00 | 20.00 | 17.60 | ||
|
FDC140VSX/FDUM140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
FDC140VSX/FDT140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.99 | 3.81 | 14.00 | 15.50 | ||
|
FDC140VSX/FDU140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
U-200PZH4E8 / S-200PE4E
2024
|
PANASONIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.02 | 3.85 | 3.55 | 19.00 | 14.50 | ||
|
FDC125VSX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VSX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
U-140PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.49 | 3.89 | 4.18 | -15° | 14.00 | 14.00 | |
|
U-140PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.51 | 3.89 | 4.18 | -15° | 14.00 | 14.00 | |
|
U-200PZH4E8 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.41 | 3.89 | 3.71 | -20° | 17.50 | 15.70 | |
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
PUZ-ZM200YKA3/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.61 | 3.50 | -20° | 19.00 | 18.90 | |
|
FDC125VSX-W/FDF125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.85 | 3.61 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDF125VH1
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.85 | 3.61 | 12.50 | 14.00 | ||
|
PUZ-ZM200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.62 | 3.50 | -20° | 19.00 | 18.90 | |
|
AUD200UX4RPH8/AUW200U6RZ8
Turbo Inverter R32
|
HISENSE | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -10° | 19.00 | 17.00 | |
|
FDC125VSX/FDT125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.04 | 4.08 | 12.50 | 14.00 | ||
|
U-250PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.75 | 3.55 | -20° | 22.00 | 17.20 | |
|
U-250PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.48 | 3.90 | 3.80 | -20° | 22.00 | 16.70 | |
|
U-200PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 3.83 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-250PZH4E8 + P‐VTVF250MC5‐PE
2025
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-200PZH4E8 / S-6071PF3E(3x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PF3E(4x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
PUZ-ZM250YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.12 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
FDC250VSA/FDE125VH/FDE125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.45 | 3.58 | 24.00 | 14.20 | ||
|
PUZ-ZM250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.13 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
FDC125VSX/FDE60VH/FDE60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.65 | 4.07 | 3.78 | 12.50 | 14.00 | ||
|
FDC250VSA-W/FDT125VH/FDT125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.35 | 3.80 | 25.00 | 14.20 | ||
|
U-200PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 3.94 | 3.80 | -20° | 19.00 | 15.70 | |
|
PUZ-M250YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.07 | 4.34 | 3.50 | -20° | 22.00 | 17.00 | |
|
FDC250VSA-W/FDE125VH/FDE125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.25 | 3.53 | 25.00 | 14.20 | ||
|
FDC280VSA-W/FDUM140VH/FDUM140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.23 | 3.54 | 27.00 | 16.00 | ||
|
U-250PZH4E8 + P‐VTVF250NC5‐PE
2025
|
PANASONIC | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-250PZH4E8 + P‐VTVF250PC5‐PE
2025
|
PANASONIC | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
FDC125VSX/FDT60VH/FDT60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.04 | 4.44 | 4.35 | 12.50 | 14.00 | ||
|
FDC250VSA/FDUM125VH/FDUM125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.50 | 3.59 | 24.00 | 14.20 | ||
|
FDC250VSA-W/FDUM125VH/FDUM125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.40 | 3.54 | 25.00 | 14.20 | ||
|
PUZ-ZM200YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.46 | 3.79 | -20° | 19.00 | 18.90 | |
|
PUZ-ZM200YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.46 | 3.79 | -20° | 19.00 | 18.90 | |
|
U-250PZH4E8 / S-6071PF3E(4x)
2024
|
PANASONIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.00 | 3.75 | -20° | 21.50 | 17.20 | |
|
FDC125VSX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.18 | 3.83 | 12.50 | 14.00 | ||
|
PUZ-M200YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.35 | 3.60 | -20° | 19.00 | 15.50 | |
|
FDC140VSX-W/FDF71VH/FDF71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.20 | 3.75 | 14.00 | 14.30 |