Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(9)
Fujitsu Atlantic
(6)
GENERAL
(6)
GREE
(0)
GSS
(0)
HAIER
(5)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(5)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(2)
MIDEA
(0)
MITSUBISHI ELECTRIC
(32)
Mitsubishi Heavy Industries
(100)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
PITSOS
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-HJ25VA/MSZ-HJ25VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.62 | -10° | 2.50 | 1.90 | |
|
AOYG60LATT/ARYG60LHTA
AOYG**L
|
FUJITSU | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
AOHG60LATT/ARHG60LHTA
AOHG**L
|
GENERAL | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
ROG60LATT/RDG60LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
AOYG60LATT/ARYG60LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
FDC250VSA/FDU250VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.82 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
MUZ-HJ35VA/MSZ-HJ35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.62 | -10° | 3.10 | 2.40 | |
|
FDC250VSA/FDU250VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.83 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
AJ080TXJ4KH / AJ020TNAPKH / AJ068TNAPKH
FJM
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.61 | -10° | 7.45 | 5.20 | |
|
UU70W U34 / UB70 N94
UU
|
LG | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.53 | 3.50 | 19.00 | 13.40 | ||
|
UU70W U34 / UB70 N95
UU
|
LG | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.53 | 3.50 | 19.00 | 13.40 | ||
|
FDC200VSA/FDU200VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.06 | 3.52 | 3.71 | 19.00 | 12.50 | ||
|
FDC200VSA/FDU200VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.07 | 3.52 | 3.71 | 19.00 | 12.50 | ||
|
FDC125VNX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.72 | 3.71 | 12.50 | 11.40 | ||
|
FDC125VSX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.74 | 3.66 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VNX/FDF125VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.98 | 3.61 | 3.61 | 12.50 | 11.40 | ||
|
AOYG45LATT/ARYG45LMLA
AOYG**L
|
FUJITSU | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.06 | 3.61 | 3.61 | 12.50 | 10.10 | ||
|
AOHG45LATT/ARHG45LMLA
AOHG**L
|
GENERAL | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.06 | 3.61 | 3.61 | 12.50 | 10.10 | ||
|
AOYG45LATT/ARYG45LMLA
AOYG**L
|
Fujitsu Atlantic | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.06 | 3.61 | 3.61 | 12.50 | 10.10 | ||
|
MXZ-3E54VA/MSZ-EF18VE3W(B)(S)/MSZ-EF35VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.54 | -15° | 5.30 | 4.80 | |
|
FDC125VSX/FDF125VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.11 | 3.61 | 3.61 | 12.50 | 13.50 | ||
|
AJ100TXJ5KH / AJ050TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.51 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
MUZ-DM25VA/MSZ-DM25VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 4.10 | 3.71 | -10° | 2.50 | 1.90 | |
|
AJ068TXJ3KH / AJ025TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.02 | 4.00 | 3.82 | -10° | 6.80 | 5.09 | |
|
AOYG45LATT
AOY**L
|
FUJITSU | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
AOHG45LATT
AOH**L Multi
|
GENERAL | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
ROG45LATT
RO**L Multi
|
FUJI ELECTRIC | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
AOYG45LATT
AOY**L
|
Fujitsu Atlantic | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
MUZ-DM35VA/MSZ-DM35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 4.10 | 3.69 | -10° | 3.10 | 2.40 | |
|
ABH140K1ERG/1UH140P1ERK
Smart Power - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 13.50 | 10.00 | ||
|
FDC140VNX/FDUM140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.85 | 3.62 | 14.00 | 13.00 | ||
|
MXZ-2D42VA2/MSZ-SF20VA/MSZ-SF20VA
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 3.80 | 4.04 | -15° | 4.00 | 4.00 | |
|
FDC140VNX/FDU140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.85 | 3.62 | 14.00 | 13.00 | ||
|
FDC125VNX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.33 | 3.88 | 3.71 | 12.50 | 11.40 | ||
|
FDC125VNX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.34 | 3.88 | 3.71 | 12.50 | 11.40 | ||
|
MXZ-2D33VA/MSZ-SF15VA/MSZ-EF18VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 4.10 | 4.17 | -15° | 3.30 | 2.70 | |
|
FDC100VSX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.11 | 3.87 | 3.71 | -20° | 10.00 | 8.20 | |
|
FDC100VSX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.17 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
FDC140VSX/FDUM140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
FDC100VNX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
FDC100VNX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 3.88 | 3.71 | -20° | 10.00 | 8.20 | |
|
FDC140VSX/FDT140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.99 | 3.81 | 14.00 | 15.50 | ||
|
FDC140VSX/FDU140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
MUZ-HJ50VA/MSZ-HJ50VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.20 | 3.65 | -10° | 5.00 | 3.80 | |
|
AJ050TXJ2KH / AJ025TNAPKH / AJ025TNAPKH
FJM
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.01 | 3.68 | -10° | 5.00 | 4.21 | |
|
AOYG45LATT/ABYG45LRTA
AOYG**L
|
FUJITSU | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
AOHG45LATT/ABHG45LRTA
AOHG**L
|
GENERAL | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
AOYG45LATT/ABYG45LRTA
AOYG**L
|
Fujitsu Atlantic | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
FDC125VSX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VSX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 |