Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(19)
ATLANTIC
(17)
AUX
(11)
BOSCH
(61)
BRYANT
(0)
Buderus
(11)
CARRIER
(45)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(301)
EQUATION
(2)
FUJI ELECTRIC
(62)
FUJITSU
(136)
Fujitsu Atlantic
(74)
GENERAL
(107)
GREE
(40)
GSS
(0)
HAIER
(116)
HEC
(2)
HEIWA
(3)
HISENSE
(124)
HITACHI
(64)
IVT
(8)
Inventor
(28)
KAYSUN
(12)
LG
(90)
MIDEA
(176)
MITSUBISHI ELECTRIC
(174)
Mitsubishi Heavy Industries
(154)
NORD
(12)
Nobu
(0)
PANASONIC
(173)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(51)
THERMOR
(16)
TOSHIBA
(102)
Viessmann
(2)
Vulcano
(2)
WESTPOINT
(6)
YORK
(8)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
H12S1D NS1/H12S1D U12
U12A
|
LG | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.35 | -10° | 3.50 | 2.80 | |
|
H12S1DA NS1 / H12S1DA U12
U12A
|
LG | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.35 | -10° | 3.50 | 2.80 | |
|
AOEG30KBTB/ARXH30KMTAP
ARXH**K
|
FUJITSU | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/ARXH30KMTAP
ARX**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
AS35XU00W/HA35XU00G
Uni HA
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU0EW/HA35XU00G
Uni HA
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU0EW/HB35XU0AG
Uni HB
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU0EW/HB35XU0BG
Uni HB
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU00W/HB35XU0AG
Uni HB
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU00W/HB35XU0BG
Uni HB
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU00W/HAXU120AG
Uni HA
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
GWH09AUCXB-K6DNA2A
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
GWH09AUCXB-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
GWH09AWCXB-K6DNA4G
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
GWH09ATCXB-K6DNA4G
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
GWH09ATCXB-K6DNA3G
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
GWH09AGCXB-K6DNA1H
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
GWH09AGCXB-K6DNA2H
MONOSPLITS
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.45 | -10° | 2.70 | 2.70 | |
|
AS35XU0AW/HA35XU00G
Uni HA
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU0FW/HA35XU00G
Uni HA
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU0FW/HB35XU0AG
Uni HB
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU0FW/HB35XU0BG
Uni HB
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU0AW/HB35XU0AG
Uni HB
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU0AW/HB35XU0BG
Uni HB
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
AS35XU0AW/HAXU120AG
Uni HA
|
HISENSE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -10° | 3.50 | 2.70 | |
|
HMIP2-25W-EUV1 / HMEP2-25-EUV1
HYOKO2
|
HEIWA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
U-50PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
RAC-DJ35WHAE / RAK-DJ35RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 4.00 | -15° | 3.50 | 2.80 | |
|
AOYG36LATT/AUYG36LRLA
AUY**L
|
FUJITSU | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.38 | -15° | 10.00 | 10.00 | |
|
SRC20ZS-W/SRK20ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
AF35S3DHRA/1U35MS3FRA
Wall mounted - Console
|
HAIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.60 | |
|
AF35S3DHRA(D)/1U35MS3FRA
Wall mounted - Console
|
HAIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX201-09AFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 2.80 | 2.60 | |
|
CL5100i 25 HE/CL5100i W 25 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 2.80 | 2.60 | |
|
MOX231-09HFN8-QRD6GW/MSCB1BU-09HRFN8-QRD1GW
Breezeless E
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 2.60 | 2.60 | |
|
EZ-09RD6-O/CB1-09HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 2.60 | 2.60 | |
|
MX2-09RD6/CB1-09HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 2.60 | 2.60 | |
|
MX2-09RD6/CB1-09HRFN8-UV
Breezeless E
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 2.60 | 2.60 | |
|
MX2H-09RD6/CB1-09HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 2.60 | 2.60 | |
|
MX2H-09RD6/MSCB1BU-09HRFN8-ME
Breezeless E
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 2.60 | 2.60 | |
|
ARXP35N / ATXP35N
ARXP
|
DAIKIN | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.62 | 4.02 | -15° | 3.50 | 2.80 | |
|
ARXP35N9 / ATXP35N9
ARXP
|
DAIKIN | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.62 | 4.02 | -15° | 3.50 | 2.80 | |
|
RAS-4M27G3AVG-E/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
38WH4M080C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
RAS-4M27G3AVG-E/RAS-B13P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 |