Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(19)
ATLANTIC
(17)
AUX
(11)
BOSCH
(61)
BRYANT
(0)
Buderus
(11)
CARRIER
(45)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(301)
EQUATION
(2)
FUJI ELECTRIC
(62)
FUJITSU
(136)
Fujitsu Atlantic
(74)
GENERAL
(107)
GREE
(40)
GSS
(0)
HAIER
(116)
HEC
(2)
HEIWA
(3)
HISENSE
(124)
HITACHI
(64)
IVT
(8)
Inventor
(28)
KAYSUN
(12)
LG
(90)
MIDEA
(176)
MITSUBISHI ELECTRIC
(174)
Mitsubishi Heavy Industries
(154)
NORD
(12)
Nobu
(0)
PANASONIC
(173)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(51)
THERMOR
(16)
TOSHIBA
(102)
Viessmann
(2)
Vulcano
(2)
WESTPOINT
(6)
YORK
(8)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHH24KMTG/ASHH24KMTGL
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
AOEH24KMTG/ASEH24KMTGL
ASE**K
|
FUJITSU | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
3MXM40A9 / CTXM15R / FTXM25R
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
3MXM40A9 / CTXM15A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
U-36PZH3E5/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.70 | 4.26 | -20° | 3.50 | 3.10 | |
|
FDC100VNA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
RAS-2.5HVRC3 / RCI-2.5FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.53 | 4.18 | 4.12 | -25° | 5.60 | 5.20 | |
|
RAS-4M27G3AVG-E/RAS-B16G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
RAS-4M27G3AVG-E/RAS-B16P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
PUZ-ZM100VDA/PLA-M100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.30 | 4.17 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PLA-M100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.30 | 4.17 | -20° | 9.50 | 7.80 | |
|
RAV-GP1101AT8-E/RAV-HM1101BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.19 | 4.06 | -20° | 10.00 | 10.80 | |
|
SRC35ZS-W2/SRR35ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.50 | 4.16 | -10° | 3.50 | 3.10 | |
|
3AMXM52N9 / ATXM25R / ATXM25R
3AMXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.34 | 4.35 | -15° | 5.00 | 4.80 | |
|
3AMXM52N9 / ATXM25A / ATXM25A
3AMXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.34 | 4.35 | -15° | 5.00 | 4.80 | |
|
M2OF-18HFN8-Q/MSOPBU-09HRFN8-QRE1GWV+MSOPBU-09HRFN8-QRE1GWV
M2OF-18HFN8-Q
|
MIDEA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
AC-5,3 MS E+ / AC186i.3-2,6 W + AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
CL7000M 53/2 E / CL7000iU W 26 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
MUZ-EF35VG/MSZ-EF35VG(K)(W)(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.21 | -15° | 3.50 | 2.90 | |
|
MUZ-EF35VG2/MSZ-EF35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.21 | -15° | 3.50 | 2.90 | |
|
U-71PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
AS35S2SJ1FA-3/1U35MECFRA-3
Super Match mono-Jade Plus
|
HAIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.75 | 4.70 | 4.70 | -10° | 3.50 | 2.65 | |
|
AS 012 JDB.UI/ 1U 012 JD.UE
Kazendo
|
ATLANTIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.75 | 4.70 | 4.70 | -10° | 3.50 | 2.65 | |
|
RZASG71MV1 / FDXM35F9 / FDXM35F9
RZASG
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.22 | 4.22 | -10° | 6.80 | 4.50 | |
|
RZASG71MV1 / FNA35A9 / FNA35A9
RZASG
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.22 | 4.22 | -10° | 6.80 | 4.50 | |
|
3MXM52A9 / CTXM15R / FTXM35R
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / CTXM15R / FTXM35R
4MWXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
3MXM52A9 / CTXM15A / FTXM35A
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / CTXM15A / FTXM35A
4MWXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXP35N9 / CTXM15A
4MWXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
MUZ-EF25VE/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.57 | -15° | 2.50 | 2.40 | |
|
RAS-4HVNC2E / RCI-4.0FS1R
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.40 | 4.30 | -20° | 10.00 | 8.70 | |
|
U-100PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 4.93 | -15° | 10.00 | 10.00 | |
|
CU-NZ25YKE / CS-NZ25YKE
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-NZ25YKE / CS-NZ25YKE-1
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
U-125PZH4E5 / S-2545PK4E(4x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E8 / S-2545PK4E(4x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-25PZ3E5 / S-25PY3E
2022
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -15° | 2.50 | 2.80 | |
|
MU3R19 U24A0 / MJ09PC NSJ0 / MJ09PC NSJ0
MU
|
LG | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.25 | -10° | 5.27 | 4.50 | |
|
FDC100VNX-W/FDT50VH/FDT50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.24 | 4.24 | 4.25 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDT50VH/FDT50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.24 | 4.24 | 4.25 | -20° | 10.00 | 11.20 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RCG09KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 |