Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(5)
ATLANTIC
(4)
AUX
(0)
BOSCH
(30)
BRYANT
(0)
Buderus
(8)
CARRIER
(17)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(101)
EQUATION
(0)
FUJI ELECTRIC
(17)
FUJITSU
(40)
Fujitsu Atlantic
(23)
GENERAL
(39)
GREE
(1)
GSS
(0)
HAIER
(36)
HEC
(0)
HEIWA
(0)
HISENSE
(1)
HITACHI
(12)
IVT
(3)
Inventor
(5)
KAYSUN
(1)
LG
(20)
MIDEA
(31)
MITSUBISHI ELECTRIC
(40)
Mitsubishi Heavy Industries
(31)
NORD
(5)
Nobu
(0)
PANASONIC
(59)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(18)
THERMOR
(0)
TOSHIBA
(51)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(3)
YORK
(1)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UUA1 UL0 / MJ09PC NSJ
UU
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.50 | -10° | 2.50 | 2.80 | |
|
UUA1 UL0 / MJ09PC NSJ0
UU
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.50 | -10° | 2.50 | 2.80 | |
|
SRC15ZTL-W/SRK15ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.40 | 4.76 | -10° | 1.50 | 2.30 | |
|
U-25PZ3E5/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 4.52 | -15° | 2.50 | 2.50 | |
|
MXZ-2D42VA2/MSZ-EF18VE3W(B)(S)/MSZ-EF25VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.84 | -15° | 4.20 | 3.20 | |
|
AOYG07KETA /ASYG07KETE
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA /ASHG07KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA /ASHG07KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA /ASYG07KETE-B
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KMCC/RSG07KMCE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA /RSG07KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KMCC/ASYG07KMCE
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETE
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETE-B
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KMCC/ASHG07KMCE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KMCC/ASYG07KMCF
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETF
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETF-B
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KMCC/ASHG07KMCF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETF-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KMCC/RSG07KMCF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETF-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOEG07KETA/ASEG07KETF
ASE**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOEG07KETA/ASEG07KETF-B
ASE**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA /ASYG07KETE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA /ASYG07KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KMCC/ASYG07KMCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KMCC/ASYG07KMCF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETF-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AS25PCHHRA-NR/1U25KEFFRA-NR
Pearl Nordic
|
HAIER | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.20 | 4.50 | -10° | 2.60 | 3.00 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
AR50F07C1AHN/AR50F07C1AHX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.20 | 4.68 | -11° | 2.00 | 2.10 | |
|
AS35PCHHRA-NR/1U35KEFFRA-NR
Pearl Nordic
|
HAIER | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.50 | -10° | 3.50 | 3.90 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
U-36PZ3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.50 | 4.62 | -15° | 3.60 | 2.80 | |
|
MUZ-BT20VG2/MSZ-BT20VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.30 | 4.55 | -15° | 2.00 | 2.20 | |
|
AS 007 JDB.UI/1U 007 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.75 | 4.20 | 4.80 | -10° | 2.40 | 2.50 | |
|
CU-2Z41TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.84 | -15° | 4.10 | 3.50 | |
|
SRC25ZTL-W/SRK25ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.70 | 4.55 | -10° | 2.50 | 2.70 | |
|
DC09RK UL2 / DC09RK NSJ
UL2
|
LG | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.50 | -10° | 2.50 | 2.80 |