Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(6)
ATLANTIC
(4)
AUX
(0)
BOSCH
(31)
BRYANT
(0)
Buderus
(8)
CARRIER
(18)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(140)
EQUATION
(0)
FUJI ELECTRIC
(27)
FUJITSU
(56)
Fujitsu Atlantic
(33)
GENERAL
(53)
GREE
(3)
GSS
(0)
HAIER
(36)
HEC
(0)
HEIWA
(0)
HISENSE
(1)
HITACHI
(12)
IVT
(3)
Inventor
(5)
KAYSUN
(1)
LG
(30)
MIDEA
(33)
MITSUBISHI ELECTRIC
(42)
Mitsubishi Heavy Industries
(38)
NORD
(5)
Nobu
(0)
PANASONIC
(64)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(18)
THERMOR
(0)
TOSHIBA
(51)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(3)
YORK
(1)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AG1-09NXD6-O(B)/AG1-09NXD6-I(B)
Extreme save R32
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
X2-09N8D6-O/AGU-09NXD1-I
Extreme save R32
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
WIMO-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS25XCAHRA+AS25XCAHRA/2U40S2SM1FA
Super Match Multi-Tundra
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.70 | |
|
AS25XCAHRA-MB+AS25XCAHRA-MB/2U40S2SM1FA
Super Match Multi-Expert
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.70 | |
|
SCM30ZS-W/SRK15ZS-WF/SRK15ZS-WF
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.07 | 4.80 | 5.41 | -10° | 3.00 | 3.30 | |
|
MUZ-EF25VEH/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
42QHE09D8SH*/38QHE09D8SH*
Wall mounted
|
CARRIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.51 | -10° | 2.64 | 2.40 | |
|
PUZ-ZM35VKA2/PEAD-M35JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/PEAD-M35JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
MOX201-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
X2AGN-09N8D6-OH/AGN-09N8D1-IH
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
WITO-09322.MH/WIT-09322.MH
WIT
|
WESTPOINT | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AITO-09322.MH/AIT-09322.MH
AIT
|
AIRCLASS | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
M2OF-18HFN8-Q/MSEPBU-09HRFN8-QRD6GW+MSEPBU-09HRFN8-QRD6GW
M2OF-18HFN8-Q
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
ZDAB-2050-09M25/HDHC-025N-09M25x2
ZDAB
|
AIRWELL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
MOX230-09HFN8-QRD6GW/MSEPBU-09HRFN8-QRD6GW
All easy-R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
LEUVO-09/LEUVI-09WFI
Leon
|
Inventor | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
LHUVO-09/LHUVI-09WFI
Leon
|
Inventor | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
LEUVOCP-09/LEUVICP-09WFI
Leon
|
Inventor | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
KAE-26 DR9/KAY-P 26 DR12
SUITE Prodigy PRO
|
KAYSUN | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
MOX2-09HFN8AD/MSEP-09HFN8AD
All easy-R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
YHKF09XEEDMH-RY / YHKF09YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.60 | -10° | 2.60 | 2.40 | |
|
2U 018 NBB.UE/AS 009 JDB.UI/AS 012 JDB.UI
Super Match Multi
|
ATLANTIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.71 | -10° | 4.60 | 4.00 | |
|
AJ040TXJ2KG / AR70F07CAAW / AR70F07CAAW
FJM
|
SAMSUNG | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.54 | 4.64 | 4.67 | -10° | 4.00 | 3.05 | |
|
AJ040TXJ2KG / AR70H07CAAW / AR70H07CAAB
FJM
|
SAMSUNG | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.54 | 4.64 | 4.67 | -10° | 4.00 | 3.05 | |
|
RAV-GM401ATP-E/RAV-HM401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.34 | 5.10 | 5.13 | -15° | 3.60 | 2.70 | |
|
3MXM40A9 / FTXM20R / FTXM20R
3MXM
|
DAIKIN | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.53 | 4.24 | 4.73 | -15° | 4.00 | 4.80 | |
|
3MXM40A9 / FTXM20A / FTXM20A
3MXM
|
DAIKIN | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.53 | 4.24 | 4.73 | -15° | 4.00 | 4.80 | |
|
CU-Z20XKE / CS-Z20XKEW
2021
|
PANASONIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.80 | 4.52 | -15° | 2.10 | 2.10 | |
|
CU-Z20XKE / CS-XZ20XKEW
2021
|
PANASONIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.80 | 4.52 | -15° | 2.10 | 2.10 | |
|
U-100PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.93 | -15° | 10.00 | 10.00 | |
|
3MXM40A9 / CTXM15R / FTXM25R
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
3MXM40A9 / CTXM15A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
RAS-4M27G3AVG-E/RAS-B16G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
RAS-4M27G3AVG-E/RAS-B16P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
M2OF-18HFN8-Q/MSOPBU-09HRFN8-QRE1GWV+MSOPBU-09HRFN8-QRE1GWV
M2OF-18HFN8-Q
|
MIDEA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
AC-5,3 MS E+ / AC186i.3-2,6 W + AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
CL7000M 53/2 E / CL7000iU W 26 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
AS35S2SJ1FA-3/1U35MECFRA-3
Super Match mono-Jade Plus
|
HAIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.75 | 4.70 | 4.70 | -10° | 3.50 | 2.65 | |
|
AS 012 JDB.UI/ 1U 012 JD.UE
Kazendo
|
ATLANTIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.75 | 4.70 | 4.70 | -10° | 3.50 | 2.65 | |
|
3MXM52A9 / CTXM15R / FTXM35R
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / CTXM15R / FTXM35R
4MWXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
3MXM52A9 / CTXM15A / FTXM35A
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / CTXM15A / FTXM35A
4MWXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXP35N9 / CTXM15A
4MWXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
MUZ-EF25VE/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.57 | -15° | 2.50 | 2.40 | |
|
U-100PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 4.93 | -15° | 10.00 | 10.00 |