Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(0)
AUX
(0)
BOSCH
(2)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(6)
GSS
(0)
HAIER
(5)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(4)
IVT
(0)
Inventor
(0)
KAYSUN
(2)
LG
(0)
MIDEA
(16)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AD140S2SM3FA/1U140S2SP1FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.73 | 13.40 | 11.00 | ||
|
RPFC-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.01 | 3.55 | -15° | 6.50 | 6.00 | |
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(GA)/MUEU-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
FDMX-050N-09M25/YDAX-050H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MO-18N8-Q/MUEU-18NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
KUE-52 DVR13/KPC-52 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)-GR/MUEU-18HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(GA)/MUEU2-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(H)/MUE-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(H)/MUEU-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
AD140S2SM3FA/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
MOX430U-24HFN8-QRD1W(GA)/MUE-24HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MOX430U-24HFN8-QRD1W/MUE-24HRFNX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MOX430U-24HFN8-Q1(GA)/MUE-24HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MO-24N8-Q-1/MUE-24NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MOX430U-24HFN8-Q1(GA)/MUE2-24HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
KUE-71 DVR14/KPC-71 DR14
Ceiling&Floor R32
|
KAYSUN | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MO-24N8-Q-1/MUE-24NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MOX430U-24HFN8-Q1(H)/MUE-24HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
CL5001L 70 E / CL5000iL CF 70 E
Climate 5001 L
|
BOSCH | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
FDMX-070N-09M25/YDAX-070H-09M25 2026
FDMX
|
AIRWELL | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
AD140S2SM8FA/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM8FA(H)/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM9FA(H)/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AUV125UR4RC8/AUW125U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.30 | 3.65 | -10° | 12.10 | 9.00 | |
|
GUD100ZD1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GUD50ZD1/A-S/GUD50W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | -10° | 5.30 | 3.90 | ||
|
AUV140UR4RC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
AUV140UR4RC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
GUD35ZD1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.10 | -10° | 3.50 | 3.10 | ||
|
AUV125UR4RC8/AUW125U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
AUV125UR4RC8/AUW125U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
GUD85ZD1/A-S/GUD85W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.50 | -10° | 8.50 | 6.00 | ||
|
GUD71ZD1/A-S/GUD71W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | -10° | 7.10 | 4.70 | ||
|
RAC-XJ25FHAE / RAF-XJ25RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.50 | 4.60 | 4.50 | -20° | 2.50 | 2.77 | |
|
RAC-XJ35FHAE / RAF-XJ35RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.20 | 4.61 | 3.90 | -20° | 3.50 | 3.02 | |
|
RAC-XJ50FHAE / RAF-XJ50RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 7.30 | 4.30 | 3.90 | -20° | 5.00 | 4.19 |