Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(1)
ATLANTIC
(0)
AUX
(5)
BOSCH
(4)
BRYANT
(0)
Buderus
(2)
CARRIER
(9)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(110)
DE DIETRICH
(1)
EQUATION
(0)
FUJI ELECTRIC
(5)
FUJITSU
(20)
Fujitsu Atlantic
(7)
GENERAL
(11)
GREE
(18)
GSS
(0)
HAIER
(21)
HEC
(0)
HEIWA
(1)
HISENSE
(66)
HITACHI
(34)
IVT
(1)
Inventor
(5)
KAYSUN
(2)
LG
(38)
MIDEA
(16)
MITSUBISHI ELECTRIC
(130)
Mitsubishi Heavy Industries
(132)
NORD
(3)
Nobu
(0)
PANASONIC
(43)
PITSOS
(0)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(17)
THERMOR
(0)
TOSHIBA
(49)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(4)
XTRON
(0)
YORK
(1)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VNX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.72 | 3.71 | 12.50 | 11.40 | ||
|
FDC125VSX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.74 | 3.66 | 3.71 | 12.50 | 14.00 | ||
|
SUZ-SM71VA/PLA-SM71EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA2/PLA-SM71EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
FDC100VNX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
FDC100VSX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
FDC100VSX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.88 | 3.84 | 3.20 | -20° | 10.00 | 10.70 | |
|
AB71S2SG1FA/1U71S2ST1FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.08 | 4.00 | 3.30 | -10° | 7.10 | 5.00 | |
|
UUC1 U40 / UM30F NA0
U4
|
LG | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.71 | -10° | 7.50 | 5.40 | |
|
UUD1 U30 / US36F NR0
UU
|
LG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.85 | 3.90 | -10° | 9.50 | 8.70 | |
|
UUD3 U30 / US36F NR0
UU
|
LG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.85 | 3.90 | -10° | 9.50 | 8.70 | |
|
GVH24AMXF-K6DNC7A
Floor-standing
|
GREE | Floor standing | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.39 | -10° | 7.20 | 5.60 | |
|
FDC125VNX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.33 | 3.88 | 3.71 | 12.50 | 11.40 | ||
|
FDC125VNX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.34 | 3.88 | 3.71 | 12.50 | 11.40 | ||
|
FDC100VSX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.11 | 3.87 | 3.71 | -20° | 10.00 | 8.20 | |
|
FDC100VSX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.17 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
FDC100VNX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
FDC100VNX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 3.88 | 3.71 | -20° | 10.00 | 8.20 | |
|
RAS-2HVRC3 / RPK-2.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.88 | 3.91 | -25° | 5.00 | 5.00 | |
|
CU-3Z52TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 4.02 | -15° | 5.20 | 5.00 | |
|
PUZ-ZM125YDA2/PLA-M125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.99 | 3.50 | -20° | 12.50 | 9.30 | |
|
UUD1 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD1 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
FDC125VSX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VSX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
MXZ-6F120VF2/MSZ-AP60VG/MSZ-AP60VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 3.80 | 4.24 | -15° | 9.60 | 9.70 | |
|
MXZ-6F120VF3/MSZ-AP60VGK(P)2/MSZ-AP60VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 3.80 | 4.24 | -15° | 9.60 | 9.70 | |
|
RZASG100MV1 / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | -10° | 9.50 | 6.00 | ||
|
PUZ-ZM125YDA/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PLA-M125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
MU4R27 U42 / MJ09PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.70 | 3.80 | 3.60 | -10° | 6.80 | 6.70 | |
|
RAS-2HVRC3 / RCIM-2.0FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.57 | 3.81 | 3.85 | -25° | 5.00 | 5.00 | |
|
UUC1 U40 / UM30F N10
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
UUC1 U40 / UM30F N11
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
RAS-2.5HVRC3 / RPK-2.5FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.04 | 3.94 | 3.71 | -25° | 5.60 | 5.20 | |
|
ADH125H1ERG/1UH125P1ERG
Smart Power - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 12.50 | 10.00 | ||
|
ADH125H1ERG/1UH125P1ERK
Smart Power - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 12.50 | 10.00 | ||
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
FDC125VNX/FDT125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.09 | 4.08 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.95 | 3.93 | 2.20 | 12.50 | 14.00 | ||
|
RAS-2.5HVRC3 / RCIM-2.5FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.86 | 3.71 | -25° | 5.60 | 5.20 | |
|
3AMW72U4RJC/HA35XU00G/HA35XU00G
Uni HA
|
HISENSE | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.21 | -10° | 6.20 | 5.00 | |
|
3AMW72U4RJC/HB35XU0AG/HB35XU0AG
Uni HB
|
HISENSE | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.21 | -10° | 6.20 | 5.00 | |
|
3AMW72U4RJC/HB35XU0BG/HB35XU0BG
Uni HB
|
HISENSE | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.21 | -10° | 6.20 | 5.00 |