Filters · 2 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(16)
ATLANTIC
(21)
AUX
(4)
BOSCH
(64)
BRYANT
(0)
Buderus
(20)
CARRIER
(45)
CIAT
(5)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(2)
DAIKIN
(325)
EQUATION
(0)
FUJI ELECTRIC
(39)
FUJITSU
(100)
Fujitsu Atlantic
(49)
GENERAL
(85)
GREE
(48)
GSS
(0)
HAIER
(148)
HEC
(0)
HEIWA
(4)
HISENSE
(164)
HITACHI
(65)
IVT
(9)
Inventor
(36)
KAYSUN
(7)
LG
(69)
MIDEA
(168)
MITSUBISHI ELECTRIC
(210)
Mitsubishi Heavy Industries
(140)
NORD
(18)
Nobu
(0)
PANASONIC
(168)
RIELLO
(5)
Rotenso
(0)
SAMSUNG
(85)
THERMOR
(16)
TOSHIBA
(124)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(18)
YORK
(2)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AR12TXFZBWKN/AR12TXFZBWKX
RAC
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.30 | 3.64 | -11° | 3.50 | 2.40 | |
|
AR09TXFZBWKN/AR09TXFZBWKX
RAC
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.30 | 3.95 | -11° | 2.50 | 2.30 | |
|
GWH09AGBXB-K6DNA1E
MONOSPLITS
|
GREE | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.08 | -10° | 2.70 | 2.60 | |
|
GWH09ALBXB-K6DNA2D
MONOSPLITS
|
GREE | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.08 | -10° | 2.70 | 2.60 | |
|
SRC15ZTL-W/SRK15ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.40 | 4.76 | -10° | 1.50 | 2.30 | |
|
MUZ-WN25VA/MSZ-WN25VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 3.71 | -15° | 2.50 | 1.90 | |
|
CU-FZ25WKE / CS-FZ25WKE
2019
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 4.04 | -15° | 2.50 | 1.90 | |
|
CU-BZ25XKE / CS-BZ25XKE
2022
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 4.06 | -15° | 2.50 | 1.90 | |
|
CU-UZ25ZKE / CS-UZ25ZKE
2023
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 4.06 | -15° | 2.50 | 1.90 | |
|
S3UM12EL26A / S3NM12EL26A
U18A
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA1 U18 / A12GA1 NSE
U18A
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2 U18 / A12GA2 NSE
U18A
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2U EEU / A12GA2N EEU
U18A
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2 U18T / A12GA2 NSET
U18A
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
SRC20ZTL-W/SRK20ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.40 | 4.22 | -10° | 2.00 | 2.40 | |
|
RAS-25E2AVG-ND/RAS-B25E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.45 | 4.27 | -25° | 2.50 | 2.80 | |
|
PUZ-ZM50VKA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.30 | 3.72 | -11° | 4.60 | 3.30 | |
|
PUZ-ZM50VKA2/PKA-M50LAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.30 | 3.72 | -11° | 4.60 | 3.30 | |
|
PUZ-ZM50VKA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.30 | 3.72 | -11° | 4.60 | 3.30 | |
|
PUZ-ZM50VKA3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.30 | 3.72 | -11° | 4.60 | 3.30 | |
|
U-25PZ3E5/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 4.52 | -15° | 2.50 | 2.50 | |
|
CU-BZ25ZKE / CS-BZ25ZKE
2023
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.30 | 4.09 | -15° | 2.50 | 1.90 | |
|
SUZ-M25VA2/MFZ-KT25VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.71 | -10° | 2.50 | 2.20 | |
|
A09GA1 U18 / A09GA1 NSE
U18A
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 | |
|
A09GA2 U18 / A09GA2 NSE
U18A
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 | |
|
A09GA2U EEU / A09GA2N EEU
U18A
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 | |
|
RAS-13J2AVSG-E1/RAS-B13J2FVG-E
Console
|
TOSHIBA | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 4.54 | 3.31 | -15° | 3.50 | 3.00 | |
|
MXZ-2D42VA2/MSZ-EF18VE3W(B)(S)/MSZ-EF25VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.84 | -15° | 4.20 | 3.20 | |
|
GWH09AGC-K6DNA1F
MONOSPLITS
|
GREE | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | -10° | 2.70 | 2.70 | ||
|
GWH09ACCXB-K6DNA1Y
MONOSPLITS
|
GREE | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 4.28 | -10° | 2.70 | 2.70 | |
|
CU-UZ25CKE / CS-UZ25CKE
2025
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.30 | 4.06 | -15° | 2.50 | 2.10 | |
|
SRC35ZSP-W1/SRK35ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.50 | 3.87 | -10° | 3.20 | 2.80 | |
|
RXC20E / FTXC20E
RXC
|
DAIKIN | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.73 | -14° | 2.10 | 1.90 | |
|
CU-BZ25CKE / CS-BZ25CKE
2025
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.40 | 4.09 | -15° | 2.50 | 2.10 | |
|
GEH09AAXB-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.20 | 3.97 | -10° | 2.70 | 2.60 | |
|
AS25PCHHRA-NR/1U25KEFFRA-NR
Pearl Nordic
|
HAIER | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.20 | 4.50 | -10° | 2.60 | 3.00 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ35WKE / CS-CZ35WKE
2020
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.08 | -25° | 3.50 | 3.60 | |
|
U-36PZ3E5/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 4.09 | -15° | 3.50 | 2.60 | |
|
CU-RZ35WKE / CS-RZ35WKEW
2019
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
AR50F09C1AHN/AR50F09C1AHX
RAC
|
SAMSUNG | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
GWHD(18)NK6OO GWH09YCXB-K6DNA2C/I*2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.52 | -10° | 5.30 | 4.10 | |
|
GWHD(14)NK6OO GWH(07)YCXB-K6DNA2C/I*2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.54 | -10° | 4.10 | 3.80 | |
|
RAS-07E2AVG-E/RAS-B07E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
RAS-07E2AVG-E/RAS-B07S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
38WHSM020A1A0TEE/40WHMW020D1A0TEE
40WHM
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
AS35PBPHRA-PRE/1U35MEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 3.30 | 2.80 | |
|
AS35S2SF1FA-MW3/1U35MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 |