Filters · 5 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(5)
ATLANTIC
(1)
AUX
(0)
BOSCH
(4)
BRYANT
(0)
Buderus
(0)
CARRIER
(2)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(96)
EQUATION
(0)
FUJI ELECTRIC
(8)
FUJITSU
(19)
Fujitsu Atlantic
(9)
GENERAL
(9)
GREE
(0)
GSS
(0)
HAIER
(14)
HEC
(0)
HEIWA
(0)
HISENSE
(26)
HITACHI
(21)
IVT
(2)
Inventor
(3)
KAYSUN
(2)
LG
(30)
MIDEA
(17)
MITSUBISHI ELECTRIC
(106)
Mitsubishi Heavy Industries
(72)
NORD
(4)
Nobu
(0)
PANASONIC
(44)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(23)
THERMOR
(2)
TOSHIBA
(27)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VNX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.72 | 3.71 | 12.50 | 11.40 | ||
|
FDC125VSX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.74 | 3.66 | 3.71 | 12.50 | 14.00 | ||
|
SUZ-SM71VA/PLA-SM71EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
SUZ-SM71VA2/PLA-SM71EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.00 | 3.90 | 3.50 | -10° | 7.10 | 5.80 | |
|
RAV-GM302ATP-E/RAV-HM301U1TP-E
DI
|
TOSHIBA | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.54 | 3.96 | 3.30 | -15° | 2.50 | 2.60 | |
|
ARXM71A / FHA71A9
ARXM
|
DAIKIN | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.80 | 3.60 | -15° | 6.80 | 4.50 | |
|
FDC100VNX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
FDC100VSX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
UUA1 UL0 / UQ09F NA0
UU
|
LG | Console | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.20 | -10° | 2.60 | 2.80 | |
|
RZASG71MV1 / FHA71A9
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.90 | 3.75 | -10° | 6.80 | 4.50 | |
|
SUZ-M35VA/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 2.60 | |
|
FDC100VSX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.88 | 3.84 | 3.20 | -20° | 10.00 | 10.70 | |
|
UUA1 UL0 / UQ12F NA0
UU
|
LG | Console | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.40 | 4.00 | 3.80 | -10° | 3.50 | 3.00 | |
|
AB71S2SG1FA/1U71S2ST1FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.08 | 4.00 | 3.30 | -10° | 7.10 | 5.00 | |
|
RZAG35B / FFA35A9
RZAG
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -10° | 3.50 | 4.20 | |
|
PUZ-ZM60VHA2/SLZ-M60FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/SLZ-M60FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM71VHA2/PCA-M71HA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71HA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
RZASG71MV1 / FUA71A
RZASG
|
DAIKIN | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 3.90 | 3.89 | -10° | 6.80 | 4.50 | |
|
MOX230-12HFN8-QRD0W(GA)/MFA2U-12HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MFAU-12NX-1
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
U7RS-12/V7LI-12WiFiR
Console R32
|
Inventor | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
KUE-35 DVR13/KSD-35 DR14-2
ZEN Console
|
KAYSUN | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
XDMX-035N-09M25/YDAX-035H-09M25
XDMX
|
AIRWELL | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(GA)/MFA2U-12HRFNX(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MFAU-12NX-2
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(H)/MFA2U-12HRFNX(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
AOYG09KATA/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
ROG09KATA/RCG09KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOHG09KATA/AUXG09KVLA
AUXG**K
|
GENERAL | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOEG09KATA/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOYG09KATA/AUXG09KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
PUZ-ZM125YDA2/PLA-M125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.99 | 3.50 | -20° | 12.50 | 9.30 | |
|
SUZ-M35VA2/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 3.00 | |
|
RZAG35A / FFA35A9
RZAG
|
DAIKIN | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -20° | 3.50 | 4.20 | |
|
PUZ-ZM35VKA2/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.40 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
YUKF18BYEEBMO-1/YFKF18BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
PUZ-ZM35VKA3/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.70 | |
|
RZASG100MV1 / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | 3.90 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FCAG50B / FCAG50B
RZASG
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 3.90 | -10° | 9.50 | 6.00 | ||
|
PUZ-ZM125YDA/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PLA-M125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM35VKA2/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -11° | 3.60 | 2.40 |