Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(2)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(84)
EQUATION
(0)
FUJI ELECTRIC
(8)
FUJITSU
(23)
Fujitsu Atlantic
(11)
GENERAL
(11)
GREE
(0)
GSS
(0)
HAIER
(2)
HEC
(0)
HEIWA
(0)
HISENSE
(28)
HITACHI
(12)
IVT
(0)
Inventor
(1)
KAYSUN
(2)
LG
(21)
MIDEA
(10)
MITSUBISHI ELECTRIC
(88)
Mitsubishi Heavy Industries
(36)
NORD
(1)
Nobu
(0)
PANASONIC
(18)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(0)
TOSHIBA
(9)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(2)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZASG71MV1 / FBA35A9 / FBA35A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.43 | 3.82 | 3.82 | -10° | 6.80 | 4.50 | |
|
AZAS71MV1 / FBA71A9
AZAS
|
DAIKIN | Ducted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.73 | -10° | 6.80 | 4.50 | |
|
ARXM71R / FBA71A9
ARXM
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.67 | -15° | 6.80 | 4.50 | |
|
ARXM71A / FBA71A9
ARXM
|
DAIKIN | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.67 | -15° | 6.80 | 4.50 | |
|
UUC1 U40 / UM30F NA0
U4
|
LG | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.71 | -10° | 7.50 | 5.40 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
ROG09KATA/RDG09KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOHG09KATA/ARXG09KLLAP
ARXG**K
|
GENERAL | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOEG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
RZAG50B / FDXM50F9
RZAG
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -10° | 5.00 | 4.30 | |
|
RZAG50B / FNA50A9
RZAG
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -10° | 5.00 | 4.30 | |
|
FDC125VNX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.33 | 3.88 | 3.71 | 12.50 | 11.40 | ||
|
FDC125VNX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.34 | 3.88 | 3.71 | 12.50 | 11.40 | ||
|
FDC100VSX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.11 | 3.87 | 3.71 | -20° | 10.00 | 8.20 | |
|
RZAG35B / FDXM35F9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
RZAG35B / FNA35A9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
FDC100VNX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 3.88 | 3.71 | -20° | 10.00 | 8.20 | |
|
UUB1 U20 / CL18F N60
UU
|
LG | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.28 | -10° | 5.00 | 4.10 | |
|
UUD1 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD1 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
SUZ-M25VA/SEZ-M25DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/SEZ-M25DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SEZ-M25DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
FDC125VSX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VSX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
RZAG50A / FDXM50F9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
RZAG50A / FNA50A9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
ARXM35R9 / ADEA35A
ARXM
|
DAIKIN | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 4.00 | 3.97 | -15° | 3.40 | 2.90 | |
|
PUZ-ZM71VHA2/SEZ-M71DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA2/SEZ-M71DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/SEZ-M71DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
UUC1 U40 / UM30F N10
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
UUC1 U40 / UM30F N11
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
ADH125H1ERG/1UH125P1ERG
Smart Power - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 12.50 | 10.00 | ||
|
ADH125H1ERG/1UH125P1ERK
Smart Power - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 12.50 | 10.00 | ||
|
U-36PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 4.15 | -15° | 3.40 | 2.40 | |
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
UUA1 UL0 / CL09F N50
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 4.30 | -10° | 2.50 | 2.90 | |
|
3MXM52A9 / FDXM25F9 / FDXM25F9
3MXM
|
DAIKIN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.83 | 3.69 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FDXM25F9 / FDXM25F9
4MWXM
|
DAIKIN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.83 | 3.69 | -15° | 5.00 | 4.80 | |
|
SRC40ZSX-W1/FDUM40VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.81 | 4.09 | -20° | 4.00 | 3.00 | |
|
RAV-GM402ATP-E/RAV-HM401SDTY-E
DI
|
TOSHIBA | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.00 | 4.12 | -15° | 3.60 | 2.70 | |
|
FDC125VSX-W/FDUM125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDU125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 |