Filters · 1 active
Manufacturer:
AIRCLASS
(3)
AIRWELL
(10)
ATLANTIC
(15)
AUX
(4)
BOSCH
(45)
BRYANT
(0)
Buderus
(12)
CARRIER
(29)
CIAT
(3)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(207)
EQUATION
(2)
FUJI ELECTRIC
(26)
FUJITSU
(64)
Fujitsu Atlantic
(32)
GENERAL
(55)
GREE
(19)
GSS
(0)
HAIER
(104)
HEC
(0)
HEIWA
(2)
HISENSE
(90)
HITACHI
(39)
IVT
(6)
Inventor
(21)
KAYSUN
(3)
LG
(40)
MIDEA
(104)
MITSUBISHI ELECTRIC
(139)
Mitsubishi Heavy Industries
(71)
NORD
(9)
Nobu
(0)
PANASONIC
(96)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(53)
THERMOR
(17)
TOSHIBA
(85)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(7)
YORK
(1)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
A09GA1 U18 / A09GA1 NSE
U18A
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 | |
|
A09GA2 U18 / A09GA2 NSE
U18A
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 | |
|
A09GA2U EEU / A09GA2N EEU
U18A
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 | |
|
RAS-13J2AVSG-E1/RAS-B13J2FVG-E
Console
|
TOSHIBA | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 4.54 | 3.31 | -15° | 3.50 | 3.00 | |
|
MXZ-2D42VA2/MSZ-EF18VE3W(B)(S)/MSZ-EF25VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.84 | -15° | 4.20 | 3.20 | |
|
AC026RXADKG/AC026TNXDKG
CAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.75 | -20° | 2.60 | 2.10 | |
|
AOYG07KETA /ASYG07KETE
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA /ASHG07KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA /ASHG07KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA /ASYG07KETE-B
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KMCC/RSG07KMCE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA /RSG07KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KMCC/ASYG07KMCE
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETE
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETE-B
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KMCC/ASHG07KMCE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KMCC/ASYG07KMCF
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETF
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETF-B
ASY**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KMCC/ASHG07KMCF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETF-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KMCC/RSG07KMCF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
ROG07KETA/RSG07KETF-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOEG07KETA/ASEG07KETF
ASE**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOEG07KETA/ASEG07KETF-B
ASE**K
|
FUJITSU | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA /ASYG07KETE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA /ASYG07KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KMCC/ASYG07KMCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KMCC/ASYG07KMCF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYG07KETA/ASYG07KETF-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
SRC25ZS-W2/FDTC25VH1
ZS-W
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 4.08 | -10° | 2.50 | 2.40 | |
|
AS25PCHHRA-NR/1U25KEFFRA-NR
Pearl Nordic
|
HAIER | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.20 | 4.50 | -10° | 2.60 | 3.00 | |
|
3MXM52A9 / FDXM25F9 / FDXM25F9
3MXM
|
DAIKIN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.83 | 3.69 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FDXM25F9 / FDXM25F9
4MWXM
|
DAIKIN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.83 | 3.69 | -15° | 5.00 | 4.80 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
UUA1 UL0 / UT09FH NQ0
UU
|
LG | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 4.30 | -10° | 2.50 | 2.80 | |
|
AR50F09C1AHN/AR50F09C1AHX
RAC
|
SAMSUNG | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AS35S2SF1FA-MW3/1U35MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
AS 012 NBB.UI/1U 012 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
AS35S2SF1FA-MB3/1U35MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 |