Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(12)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(1)
FUJITSU
(1)
Fujitsu Atlantic
(1)
GENERAL
(1)
GREE
(4)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(8)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(13)
Mitsubishi Heavy Industries
(99)
NORD
(0)
Nobu
(0)
PANASONIC
(11)
PITSOS
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(9)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.34 | 3.61 | 3.13 | -10° | 23.50 | 12.30 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Floor standing | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.12 | 3.53 | 2.48 | -10° | 23.50 | 12.30 | |
|
PUHZ-SHW230YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.81 | 3.51 | 3.47 | -25° | 19.00 | 23.00 | |
|
FDC125VSX/FDTC60VH/FDTC60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.81 | 3.41 | 12.50 | 14.00 | ||
|
FDC100VNX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
FDC100VSX/FDTC50VH/FDTC50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.87 | 3.20 | -20° | 10.00 | 10.80 | |
|
AOYG45LATT
AOY**L
|
FUJITSU | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
AOHG45LATT
AOH**L Multi
|
GENERAL | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
ROG45LATT
RO**L Multi
|
FUJI ELECTRIC | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
AOYG45LATT
AOY**L
|
Fujitsu Atlantic | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 | ||
|
FDC100VSX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.88 | 3.84 | 3.20 | -20° | 10.00 | 10.70 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.32 | 3.70 | 3.18 | -10° | 23.50 | 12.30 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.14 | 3.83 | 3.03 | -10° | 20.00 | 11.40 | |
|
FDC100VSX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
FDC100VNX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
U-200PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.07 | 3.87 | 3.71 | -20° | 16.00 | 15.70 | |
|
FDC280VSA-W/FDE140VH/FDE140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.95 | 3.34 | 27.00 | 16.00 | ||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.65 | 2.71 | -10° | 20.00 | 11.40 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.80 | 3.32 | -10° | 20.00 | 11.40 | |
|
FDC125VNX/FDTC60VH/FDTC60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.01 | 3.41 | 12.50 | 11.40 | ||
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.36 | 3.95 | 3.33 | -10° | 23.50 | 12.30 | |
|
PUZ-M250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.03 | 4.16 | 3.19 | -20° | 22.00 | 20.20 | |
|
U-140PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
U-140PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
FDC280VSA-W/FDT140VH/FDT140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.22 | 3.35 | 27.00 | 17.80 | ||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.32 | 3.86 | 3.24 | -10° | 20.00 | 11.40 | |
|
FDC280VSA-W/FDF140VH/FDF140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 4.13 | 3.17 | 27.00 | 17.80 | ||
|
FDC280VSA-W/FDF140VH1/FDF140VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 4.13 | 3.17 | 27.00 | 17.80 | ||
|
U-125PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
U-125PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
FDC200VSA-W/SRK100ZR-W/SRK100ZR-W
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.36 | 3.26 | 20.00 | 12.50 | ||
|
RZA200D
RZA
|
DAIKIN | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.96 | 3.82 | 19.00 | 11.20 | |||
|
RZA250D
RZA
|
DAIKIN | Floor standing | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 3.90 | 22.00 | 12.10 | |||
|
FDC125VSX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.95 | 3.93 | 2.20 | 12.50 | 14.00 | ||
|
RZA200D
RZA
|
DAIKIN | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.06 | 3.90 | 19.00 | 11.20 | |||
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
RZA250D
RZA
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.44 | 4.10 | 22.00 | 12.10 | |||
|
FDC100VNX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.92 | 4.16 | 3.20 | -20° | 10.00 | 11.20 | |
|
FDC140VNX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
FDC140VSX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
RZA250D
RZA
|
DAIKIN | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.08 | 3.86 | 22.00 | 12.10 | |||
|
RZA200D
RZA
|
DAIKIN | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.10 | 19.00 | 11.20 | |||
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 22.00 | 12.10 | |||
|
FDC100VNX-W/FDUM50VH/FDUM50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.88 | 3.79 | -20° | 10.00 | 10.00 | |
|
FDC100VSX-W/FDUM50VH/FDUM50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.88 | 3.79 | -20° | 10.00 | 10.00 | |
|
U-250PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.75 | 3.55 | -20° | 22.00 | 17.20 | |
|
U-200PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 3.83 | 3.55 | -20° | 19.00 | 16.00 | |
|
FDC250VSA/FDF125VD/FDF125VD
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.45 | 4.25 | 3.18 | 24.00 | 14.20 | ||
|
GWHD(42)NK6QO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 | |
|
GWHD(42)NK6ZO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 |