Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(16)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(37)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(12)
Fujitsu Atlantic
(9)
GENERAL
(9)
GREE
(4)
GSS
(0)
HAIER
(55)
HEC
(0)
HEIWA
(0)
HISENSE
(6)
HITACHI
(33)
IVT
(0)
Inventor
(19)
KAYSUN
(18)
LG
(9)
MIDEA
(96)
MITSUBISHI ELECTRIC
(45)
Mitsubishi Heavy Industries
(198)
NORD
(0)
Nobu
(0)
PANASONIC
(49)
RIELLO
(6)
Rotenso
(6)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(21)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(6)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-5HVNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-5HRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.79 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-5HVRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.06 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
PUZ-ZM140YDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.09 | 5.09 | 3.60 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 5.09 | 3.60 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.15 | 5.10 | 3.60 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.15 | 5.10 | 3.60 | -20° | 13.40 | 10.60 | |
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
U-200PZH4E8 / S-1014PU3E(2x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-250PZH4E8 / S-1014PU3E(2x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 6.97 | 4.18 | 3.75 | -20° | 22.00 | 17.20 | |
|
U-200PZH4E8 / S-6071PU3E(3x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PU3E(4x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-250PZH4E8 / S-6071PU3E(4x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 6.97 | 4.18 | 3.75 | -20° | 22.00 | 17.20 |