Filters · 1 active
Manufacturer:
AIRCLASS
(3)
AIRWELL
(74)
ATLANTIC
(34)
AUX
(70)
BOSCH
(109)
BRYANT
(5)
Buderus
(30)
CARRIER
(131)
CIAT
(43)
COLIBRI
(5)
CONFORT AIR
(3)
Candy
(12)
DAIKIN
(797)
EQUATION
(4)
FUJI ELECTRIC
(136)
FUJITSU
(356)
Fujitsu Atlantic
(171)
GENERAL
(198)
GREE
(118)
GSS
(3)
HAIER
(548)
HEC
(4)
HEIWA
(8)
HISENSE
(256)
HITACHI
(161)
IVT
(8)
Inventor
(134)
KAYSUN
(65)
LG
(343)
MIDEA
(738)
MITSUBISHI ELECTRIC
(564)
Mitsubishi Heavy Industries
(415)
NORD
(52)
Nobu
(6)
PANASONIC
(280)
RIELLO
(45)
Rotenso
(8)
SAMSUNG
(132)
THERMOR
(44)
TOSHIBA
(288)
Viessmann
(21)
Vulcano
(16)
WESTPOINT
(19)
YORK
(38)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG14KETA/ASYG14KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOYG14KMCC/ASYG14KMCF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOYG14KETA/ASYG14KETF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOYG14KETA/ASYG14KETF-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
FDC125VNX/FDT125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.09 | 4.08 | 12.50 | 11.40 | ||
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(GA)/MUEU-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
FDMX-050N-09M25/YDAX-050H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MO-18N8-Q/MUEU-18NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
KUE-52 DVR13/KPC-52 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)-GR/MUEU-18HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(GA)/MUEU2-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(H)/MUE-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(H)/MUEU-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
SUZ-SM60VA/PEAD-SM60JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-SM60VA/PEAD-SM60JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-SM60VA2/PEAD-SM60JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
MOX301-18HFN8-QRD0GW/MSEPCU-18HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.71 | -10° | 5.30 | 4.20 | |
|
MOX301-18HFN8-QRD1GW/MSCB1CU-18HRFN8-QRD1GW
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
MOX301-18HFNX/MSCB1BU -18HRFN8
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
MOM-18NXD0/MCB1-18N8
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
CB1-18HFNX-O/CB1-18HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
CB1-18HFNX-O(A)/CB1-18HRFN8-I(A)
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
CB1-18HFNX-O(R)/CB1-18HRFN8-I(R)
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
CB1-18HFNX-O(B)/CB1-18HRFN8-I(B)
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
MOX301-18HFN8-ME/MSCB1CU-18HRFN8-ME
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
MOX301-18HFNX/MSCB1CU -18HRFN8
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
CB1-18HFNX-O-GR/CB1-18HRFN8-I-GR
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
CB1-18HFNX-O/CB1-18HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
MOM-18NXD0/CB1-18HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
MX3-18RD1-CB/CB1-18HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
MX3-18RD1-CB/CB1-18HRFN8-UV
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
MX3H-18RD1-CB/CB1-18HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.50 | -10° | 5.30 | 4.20 | |
|
U-100PZ3E5 / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 3.93 | -15° | 9.00 | 9.00 | |
|
U-100PZ3E8 / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 3.93 | -15° | 9.00 | 9.00 | |
|
RAV-GM802ATW-E/RAV-HM801KRTP-E
DI
|
TOSHIBA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.05 | 3.35 | -15° | 6.70 | 5.10 | |
|
RZAG50A / FFA50A9
RZAG
|
DAIKIN | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.01 | 3.10 | -20° | 5.00 | 4.30 | |
|
PUZ-ZM125VDA/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.40 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.40 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
AC100RXADKG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.20 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.27 | -20° | 10.00 | 5.20 | |
|
AC160S2SK1FA/1U160S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.06 | 4.06 | 3.42 | 16.00 | 11.00 | ||
|
AC160S2SK1FA(H)/1U160S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.06 | 4.06 | 3.42 | 16.00 | 11.00 | ||
|
RZA250D
RZA
|
DAIKIN | Floor standing | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 3.90 | 22.00 | 12.10 | |||
|
GEH09AAXB-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.20 | 3.97 | -10° | 2.70 | 2.60 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ABHG22KRTA
ABH**K
|
GENERAL | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 |