Filters · 2 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(12)
ATLANTIC
(7)
AUX
(14)
BOSCH
(21)
BRYANT
(0)
Buderus
(6)
CARRIER
(34)
CIAT
(5)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(374)
EQUATION
(1)
FUJI ELECTRIC
(30)
FUJITSU
(85)
Fujitsu Atlantic
(35)
GENERAL
(55)
GREE
(40)
GSS
(0)
HAIER
(108)
HEC
(0)
HEIWA
(2)
HISENSE
(94)
HITACHI
(73)
IVT
(4)
Inventor
(21)
KAYSUN
(6)
LG
(139)
MIDEA
(101)
MITSUBISHI ELECTRIC
(224)
Mitsubishi Heavy Industries
(203)
NORD
(16)
Nobu
(0)
PANASONIC
(132)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(53)
THERMOR
(0)
TOSHIBA
(130)
Viessmann
(5)
Vulcano
(0)
WESTPOINT
(8)
YORK
(1)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-HJ50VA/MSZ-HJ50VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.20 | 3.65 | -10° | 5.00 | 3.80 | |
|
M3OA-18HFN8-Q(HRU)/MSAGAU-09HRFN8-QRD1GW+MSAGAU-09HRFN8-QRD1GW
M3OA-18HFN8-Q(HRU)
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.95 | -10° | 5.30 | 4.30 | |
|
SRC50ZSP-W1/SRK50ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.37 | -10° | 5.00 | 3.80 | |
|
SRC45ZSP-W1/SRK45ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.68 | -10° | 4.50 | 3.80 | |
|
ABH105H1ERG(H)/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 6.00 | |
|
FDC280VSA-W/FDT140VH/FDT140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.22 | 3.35 | 27.00 | 17.80 | ||
|
ABH105H1ERG(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
AB50S2SC2FA-1/1U50S2SJ2FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.42 | -10° | 5.00 | 4.00 | |
|
AB50S2SC2FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.42 | -10° | 5.00 | 4.00 | |
|
YDAM-050R-09M25/CDHM-050N-09M22
OASIS
|
AIRWELL | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.42 | -10° | 5.00 | 4.00 | |
|
AB50S2SC2FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.42 | -10° | 5.00 | 4.00 | |
|
M4OA-27HFN8-Q(HRU)/MCA4U-09HRFNX-QRD1W(GA)+MCA4U-18HRFNX-QRD1W(GA)
M4OA-27HFN8-Q(HRU)
|
MIDEA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 7.90 | 6.30 | |
|
RAV-GV1601ATP-E1/RAV-HM1601UTP-E
DIC 1ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.46 | -15° | 13.00 | 8.00 | |
|
RXC60E / FTXC60E
RXC
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.81 | -14° | 6.20 | 4.10 | |
|
ARXC60E / ATXC60E
ARXC
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.71 | -14° | 6.20 | 4.10 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
RAV-GM1401ATP-E1/RAV-HM1401UTP-E
DI
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
AS42XCAHRA-1/1U42S2SM1FA
Supermatch Expert White
|
HAIER | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 4.20 | 3.60 | |
|
AS42XCAHRA-MB1/1U42S2SM1FA
Supermatch Expert Black
|
HAIER | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 4.20 | 3.60 | |
|
AUW52U4RS7/AKT52UR4RK8
Super Inverter R32
|
HISENSE | Console | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.50 | -10° | 4.90 | 3.50 | |
|
SRC50ZTL-W/SRK50ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.58 | -10° | 5.00 | 4.00 | |
|
RXC60D / FTXC60D
RXC
|
DAIKIN | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.24 | 3.81 | -14° | 6.21 | 4.10 | |
|
MUZ-DW50VF/MSZ-DW50VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF/MSZ-HR50VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF2/MSZ-HR50VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
AS71S2SF1FA-BH/1U71S2ST1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.26 | -10° | 7.00 | 5.60 | |
|
AS71S2SF1FA-WH/1U71S2ST1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.26 | -10° | 7.00 | 5.60 | |
|
RZAG71NV1 / FAA71B
RZAG
|
DAIKIN | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.58 | 4.20 | 3.42 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FAA71B
RZAG
|
DAIKIN | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.58 | 4.20 | 3.42 | -10° | 6.80 | 4.70 | |
|
AB71S2SA1FA(H)/1U71S2SR3FA
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.72 | -10° | 6.90 | 5.00 | |
|
AB71S2SR1FA(H)/1U71S2SR2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.72 | -10° | 7.10 | 5.00 | |
|
AS68RDAHRA-4/1U68MRAFRA-4
Revive Plus
|
HAIER | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.61 | -10° | 6.20 | 4.60 | |
|
AS68RDAHRA-PL/1U68MRAFRA-4
Revive Plus
|
HAIER | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.61 | -10° | 6.20 | 4.60 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3A(C*)x2
C SERIES
|
AUX | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.44 | 4.34 | 3.90 | -10° | 5.00 | 3.80 | |
|
CU-BZ50ZKE / CS-BZ50ZKE
2023
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.42 | -15° | 5.00 | 4.00 | |
|
FDC200VSA-W/SRK100ZR-W/SRK100ZR-W
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.36 | 3.26 | 20.00 | 12.50 | ||
|
FDC125VNA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC125VSA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
CU-BZ50CKE / CS-BZ50CKE
2025
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.42 | -15° | 5.00 | 4.00 | |
|
AZAS140MY1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
AZAS140MV1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
CU-CZ35WKE / CS-CZ35WKE
2020
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.08 | -25° | 3.50 | 3.60 | |
|
RCI-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -15° | 8.70 | 7.20 | |
|
ARXC50D / ATXC50D
ARXC
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.37 | 3.71 | -14° | 5.08 | 3.90 | |
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
AM2-H18/4DR3D+AMWM-H09/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
RXYM52M(2)-T1B+FTXM26CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
RXYM52M(2)-T1B+FTXM26CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 |