Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(55)
ATLANTIC
(22)
AUX
(63)
BOSCH
(63)
BRYANT
(2)
Buderus
(20)
CARRIER
(96)
CIAT
(35)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(4)
DAIKIN
(717)
EQUATION
(3)
FUJI ELECTRIC
(111)
FUJITSU
(297)
Fujitsu Atlantic
(140)
GENERAL
(155)
GREE
(65)
GSS
(2)
HAIER
(438)
HEC
(1)
HEIWA
(4)
HISENSE
(177)
HITACHI
(143)
IVT
(5)
Inventor
(94)
KAYSUN
(54)
LG
(235)
MIDEA
(526)
MITSUBISHI ELECTRIC
(493)
Mitsubishi Heavy Industries
(370)
NORD
(38)
Nobu
(4)
PANASONIC
(225)
RIELLO
(36)
Rotenso
(8)
SAMSUNG
(113)
THERMOR
(29)
TOSHIBA
(216)
Viessmann
(17)
Vulcano
(12)
WESTPOINT
(8)
YORK
(28)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAM-G43N2HAE / RAK-XJ18QHAE / RAK-XJ25RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 4.30 | 3.50 | |
|
RAM-G36N2HBE / RAK-XJ18QHAE / RAK-XJ18QHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 3.60 | 3.50 | |
|
RAM-G43N2HBE / RAK-XJ18QHAE / RAK-XJ25RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 4.30 | 3.50 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.83 | 4.31 | 4.31 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.83 | 4.31 | 4.31 | 13.40 | 9.52 | ||
|
MOX430-24HFN8-QRD6GW/MSGPDU-24HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MOX430-24HFN8-QRD6GW/MSEZDU-24HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6-O/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6H-O/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6-O/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6H-O/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
HDMC-070N-09M25/YDA*-070*-09M25
Harmonia
|
AIRWELL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4-24RD6/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4-24RD6/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4H-24RD6/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4H-24RD6/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
42QCE024D8SH/38QCE024D8SH
Wall mounted
|
CARRIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
FDC125VSX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.26 | 2.79 | 12.50 | 14.00 | ||
|
RAS-50G3AVSG-ND/RAS-B50G3KVSG-ND
SHORAI
|
TOSHIBA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 4.00 | -25° | 5.00 | 5.00 | |
|
SRC63ZTL-W/SRK63ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.53 | -10° | 6.30 | 5.30 | |
|
RZAG50A / FBA50A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.80 | -20° | 5.00 | 4.30 | |
|
RAC-VJ60WHAE / RAK-V60RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.80 | -15° | 6.00 | 4.80 | |
|
AJ120HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ035HEAPKG / AJ035HEAPKG
FJM
|
SAMSUNG | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.45 | 3.61 | -10° | 12.00 | 8.37 | |
|
RAM-Y70N4HAE / RAK-XJ35RHBE / RAK-XJ35RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 7.00 | 5.90 | |
|
AOYG14KMCEN/ASYG14KMCEN
ASY**K
|
FUJITSU | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
AOHG14KMCEN/ASHG14KMCEN
ASH**K
|
GENERAL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
AOYG14KMCEN/ASEG14KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
AOHG14KMCEN/ASHG14KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.86 | -25° | 4.20 | 4.20 | |
|
UUD1 U30 / UT48FH NA0
UU
|
LG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.50 | 3.71 | 13.40 | 9.50 | ||
|
UUD3 U30 / UT48FH NA0
UU
|
LG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.50 | 3.71 | 13.40 | 9.50 | ||
|
RXM50R / FVXM50A9
RXM
|
DAIKIN | Floor standing | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.31 | 3.81 | -15° | 5.00 | 4.10 | |
|
PUZ-ZM100VDA/PKA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PKA-M100KAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PKA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PKA-M100KAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.61 | -20° | 9.50 | 7.80 | |
|
FDC125VNX/FDT60VH/FDT60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.83 | 4.46 | 4.35 | 12.50 | 11.40 | ||
|
UUD1 U30 / UV42FH N20
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.60 | 12.10 | 9.50 | ||
|
UUD3 U30 / UV42FH N20
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.60 | 12.10 | 9.50 | ||
|
5MWXM90A9 / FBA125A
5MWXM
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.14 | 4.02 | -15° | 9.00 | 6.46 | |
|
RZAG71NV1 / FBA71A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FBA71A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | -10° | 6.80 | 4.70 | ||
|
AUC140UR4RKC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
AUC140UR4RKC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
RXM50A8 / FVXM50B
RXM
|
DAIKIN | Floor standing | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.26 | 3.72 | -20° | 5.00 | 4.10 | |
|
RAC-50NPE / RAI-50RPE
RAC-NPE(D)
|
HITACHI | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.84 | 4.37 | 3.82 | -15° | 5.00 | 4.30 | |
|
RAC-70NPD / RAK-70PPD
RAC-NPE(D)
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.41 | 3.81 | -15° | 7.00 | 6.40 | |
|
U-100PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.93 | -15° | 10.00 | 10.00 | |
|
AC100RXADKG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.50 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.55 | -20° | 10.00 | 5.30 |