Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(0)
AUX
(4)
BOSCH
(3)
BRYANT
(0)
Buderus
(0)
CARRIER
(4)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(162)
EQUATION
(0)
FUJI ELECTRIC
(14)
FUJITSU
(33)
Fujitsu Atlantic
(14)
GENERAL
(16)
GREE
(6)
GSS
(0)
HAIER
(3)
HEC
(0)
HEIWA
(0)
HISENSE
(32)
HITACHI
(26)
IVT
(0)
Inventor
(3)
KAYSUN
(3)
LG
(35)
MIDEA
(13)
MITSUBISHI ELECTRIC
(93)
Mitsubishi Heavy Industries
(144)
NORD
(0)
Nobu
(0)
PANASONIC
(31)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(16)
THERMOR
(0)
TOSHIBA
(43)
Viessmann
(3)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC280VSA-W/FDT140VH/FDT140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.22 | 3.35 | 27.00 | 17.80 | ||
|
ABH105H1ERG(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
RAV-GV1601ATP-E1/RAV-HM1601UTP-E
DIC 1ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.46 | -15° | 13.00 | 8.00 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
RAV-GM1401ATP-E1/RAV-HM1401UTP-E
DI
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
FDC200VSA-W/SRK100ZR-W/SRK100ZR-W
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.36 | 3.26 | 20.00 | 12.50 | ||
|
FDC125VNA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC125VSA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
AZAS140MY1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
AZAS140MV1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
RCI-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -15° | 8.70 | 7.20 | |
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
FDC140VNA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
UUD1 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD3 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZTNW60GALA1
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
FDC140VNA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC140VSA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC125VNP-W/FDT125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.37 | 4.27 | 3.78 | 12.10 | 8.00 | ||
|
AZAS140MV / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
AZAS140MY / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
RAV-GM1402AT8W-E/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.20 | 3.79 | -15° | 12.10 | 8.00 | |
|
RAV-GM1101ATP-E/RAV-HM1101UTP-E
DI
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RAV-GM1101AT8P-E/RAV-HM1101UTP-E
DI 3ph
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
FDC125VNP-W/FDE125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.95 | 4.21 | 3.67 | 12.10 | 7.90 | ||
|
RAV-GM1101ATP-E/RAV-HM1101KRTP-E
DI
|
TOSHIBA | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.23 | -15° | 9.50 | 8.00 | |
|
RAV-GM1101AT8P-E/RAV-HM1101KRTP-E
DI 3ph
|
TOSHIBA | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.23 | -15° | 9.50 | 8.00 | |
|
RAV-GM1102AT8W-E/RAV-HM1101KRTP-E
DI 3ph
|
TOSHIBA | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.31 | -15° | 9.50 | 8.00 | |
|
UUD1 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD3 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD1 U30TK / ZTNW48GALA1
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
PUZ-SM140VKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
MOD30U-30HFN8-QRD0W(GA)/MCD1-30HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
MOD30U-30HFN8-Q(GA)/MCD1-30HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
MO-30N8-Q/MCD-30NX
Cassette R32
|
MIDEA | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
KUE-90 DVR13/KCIS-90 DR14
ZEN Cassette
|
KAYSUN | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
U7RS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
YUKF30BYEEBMO-1/YKKF30BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
MOD30U-30HFN8-QRD1W(GA)/MCD1-30HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
MOD30U-30HFN8-Q1(GA)/MCD1-30HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
MO-30N8-Q-1/MCD-30NX
Cassette R32
|
MIDEA | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
MOD30U-30HFN8-Q1(GA)/MCD2-30HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
KUE-90 DVR14/KCIS-90 DR14
Cassette R32
|
KAYSUN | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
MO-30N8-Q-1/MCD-30NX
Cassette R32
|
MIDEA | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
42QTD030D8S*/38QUS030D8SX*
Cassette
|
CARRIER | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 |