Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(5)
AUX
(10)
BOSCH
(13)
BRYANT
(0)
Buderus
(1)
CARRIER
(31)
CIAT
(16)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(247)
EQUATION
(0)
FUJI ELECTRIC
(57)
FUJITSU
(154)
Fujitsu Atlantic
(74)
GENERAL
(73)
GREE
(10)
GSS
(0)
HAIER
(172)
HEC
(0)
HEIWA
(0)
HISENSE
(43)
HITACHI
(66)
IVT
(0)
Inventor
(35)
KAYSUN
(36)
LG
(85)
MIDEA
(180)
MITSUBISHI ELECTRIC
(269)
Mitsubishi Heavy Industries
(294)
NORD
(8)
Nobu
(0)
PANASONIC
(88)
RIELLO
(17)
Rotenso
(8)
SAMSUNG
(27)
THERMOR
(3)
TOSHIBA
(99)
Viessmann
(8)
Vulcano
(1)
WESTPOINT
(0)
YORK
(16)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
PUZ-M125VKA2/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA3/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
AD140S2SM3FA/1UH140P1ERG
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.43 | 13.40 | 10.00 | ||
|
AD140S2SM3FA/1UH140P1ERK
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.43 | 13.40 | 10.00 | ||
|
ADH140H1ERG/1UH140P1ERG
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 14.00 | 11.00 | ||
|
ADH140H1ERG/1UH140P1ERK
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 14.00 | 11.00 | ||
|
RZA250D
RZA
|
DAIKIN | Cassette | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 22.00 | 12.10 | |||
|
RZA200D
RZA
|
DAIKIN | Cassette | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 19.00 | 11.20 | |||
|
U-100PZ3E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-125PZ3E5 / S-1014PF3E
2021
|
PANASONIC | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.52 | 3.68 | 3.56 | -15° | 12.10 | 9.30 | |
|
U-100PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
AUW105U4RK7/AUV105UR4RC8
Super Inverter R32
|
HISENSE | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -10° | 9.50 | 8.00 | |
|
YUKF55BYOEBMO-1/YKKF55BXOEBM-R1
Grande Cassette R32
|
YORK | Cassette | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.22 | -15° | 15.30 | 11.90 | |
|
U-125PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.49 | 3.68 | 3.56 | -15° | 12.10 | 9.30 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 4.19 | 3.74 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 4.19 | 3.74 | -15° | 12.10 | 7.60 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Cassette | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.88 | 3.92 | 3.92 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Cassette | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.88 | 3.92 | 3.92 | 12.10 | 9.52 | ||
|
V6FO-60/V6FI-60
Floor Standing
|
Inventor | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.70 | 3.75 | -10° | 14.00 | 10.79 | |
|
FDC140VNA/FDE140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.15 | 3.51 | 13.60 | 10.50 | ||
|
FDC140VSA/FDE140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.15 | 3.51 | 13.60 | 10.50 | ||
|
PUZ-ZM125YDA/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.37 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.37 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
ADH125H1ERG/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.97 | 3.43 | 12.40 | 8.00 | ||
|
U-125PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
U-125PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.52 | 3.94 | 3.94 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.52 | 3.94 | 3.94 | 13.40 | 9.52 | ||
|
ADH140H1ERG/1U140S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.98 | 3.97 | 3.43 | 13.40 | 8.50 | ||
|
RAV-GM1602AT8W-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.96 | 3.43 | -15° | 14.00 | 8.40 | |
|
AD125S2SM3FA/1U125S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.54 | -10° | 12.10 | 8.00 | |
|
AD125S2SM3FA/1U125S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.57 | -10° | 12.10 | 8.00 | |
|
YUKF48BYOEBMO-1/YFKF48BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling/Floor | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -15° | 14.00 | 11.20 | |
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
42QZL048D8S/38QUS048D8S
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
UUD1 U30 / UM60F N30
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD3 U30 / UM60F N30
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZBNW60GM3A1
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD1 U30 / UM60F N31
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD3 U30 / UM60F N31
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
RAV-GM2243AT8P-E/RAV-RM2241DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 3.80 | 3.24 | -10° | 19.00 | 11.40 |