Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(3)
AUX
(6)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(10)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(76)
EQUATION
(0)
FUJI ELECTRIC
(8)
FUJITSU
(25)
Fujitsu Atlantic
(8)
GENERAL
(7)
GREE
(0)
GSS
(0)
HAIER
(34)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(12)
IVT
(0)
Inventor
(7)
KAYSUN
(0)
LG
(22)
MIDEA
(0)
MITSUBISHI ELECTRIC
(41)
Mitsubishi Heavy Industries
(56)
NORD
(0)
Nobu
(0)
PANASONIC
(17)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(9)
THERMOR
(0)
TOSHIBA
(27)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC25S2SG2FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.50 | 2.80 | |
|
SUZ-M35VA/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 2.60 | |
|
AC 024 DB.UI/1U 024 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.26 | -10° | 7.10 | 5.00 | |
|
PUZ-M140YKA2/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA2/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA3/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA3/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
SUZ-M35VA2/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 3.00 | |
|
42QZL060D8S/38QUS060D8TX
Ceiling suspended
|
CARRIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
PUZ-ZM35VKA2/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.40 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
42QZL048D8S/38QUS048D8TX
Ceiling suspended
|
CARRIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
AC140S2SK2FA(H)/1U140S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.05 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.05 | 13.40 | 8.50 | ||
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
YUKF18BYEEBMO-1/YFKF18BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
RZASG100MV1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | -10° | 9.50 | 6.00 | ||
|
PUZ-ZM35VKA3/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.70 | |
|
AC140S2SK1FA/1U140S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.02 | 13.40 | 8.50 | ||
|
AC140S2SK1FA(H)/1U140S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.02 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.02 | 13.40 | 8.50 | ||
|
AC140S2SK1FA/1U140S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.51 | 13.40 | 11.00 | ||
|
42HU60VDS8C/38HU60VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
42QZL060D8S*/38QUS060D8T*
Ceiling suspended
|
CARRIER | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
SC217HIDS8/AIC217HIDT8
Ceiling suspended
|
RIELLO | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
AC25S2SG1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 2.50 | 2.80 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
YUKF24BYEEBMO-1/YFKF24BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
AC71S2SG1FA/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
AC125S2SK2FA(H)/1U125S2SN3FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | 12.30 | 8.30 | ||
|
AC125S2SK2FA(H)/1U125S2SN3FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | 12.30 | 8.30 | ||
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
AC105S2SH1FA/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 4.00 | 3.50 | -10° | 9.50 | 6.00 | |
|
42HU18VDS8C/38HU18VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
SC250HIDS8/AIC250HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
42QZL018D8S*/38QUS018D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
Vitoclima100-SIFCAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ceiling suspended
|
Viessmann | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
UUD1 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
UUD3 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
42HU48VDS8C/38HU48VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.06 | 14.00 | 11.20 | ||
|
42QZL048D8S*/38QUS048D8T*
Ceiling suspended
|
CARRIER | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.06 | 14.00 | 11.20 | ||
|
SC213HIDS8/AIC213HIDT8
Ceiling suspended
|
RIELLO | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.06 | 14.00 | 11.20 | ||
|
PUZ-M125VKA2/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA3/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 |