Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(81)
ATLANTIC
(36)
AUX
(70)
BOSCH
(121)
BRYANT
(6)
Buderus
(34)
CARRIER
(146)
CIAT
(41)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(657)
EQUATION
(5)
FUJI ELECTRIC
(128)
FUJITSU
(300)
Fujitsu Atlantic
(152)
GENERAL
(202)
GREE
(119)
GSS
(4)
HAIER
(409)
HEC
(5)
HEIWA
(7)
HISENSE
(340)
HITACHI
(135)
IVT
(10)
Inventor
(133)
KAYSUN
(65)
LG
(304)
MIDEA
(783)
MITSUBISHI ELECTRIC
(527)
Mitsubishi Heavy Industries
(344)
NORD
(56)
Nobu
(8)
PANASONIC
(271)
RIELLO
(44)
Rotenso
(8)
SAMSUNG
(182)
THERMOR
(44)
TOSHIBA
(270)
Viessmann
(24)
Vulcano
(14)
WESTPOINT
(22)
YORK
(35)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UUD1 U30 / UV48F N20
UU
|
LG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.25 | 13.40 | 9.50 | ||
|
UUD3 U30 / UV48F N20
UU
|
LG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.25 | 13.40 | 9.50 | ||
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
UUA1 UL0 / UT09FH NQ0
UU
|
LG | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 4.30 | -10° | 2.50 | 2.80 | |
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
RAV-GM402ATP-E/RAV-HM401SDTY-E
DI
|
TOSHIBA | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.00 | 4.12 | -15° | 3.60 | 2.70 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
AM2-H18/4DR3D+AMWM-H09/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
RXYM52M(2)-T1B+FTXM26CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
RXYM52M(2)-T1B+FTXM26CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.90 | -10° | 5.30 | 4.00 | |
|
RXP60N / FTXP60N
RXP
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 4.10 | 3.63 | -15° | 6.00 | 4.80 | |
|
RXP60N9 / FTXP60N
RXP
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 4.10 | 3.63 | -15° | 6.00 | 4.80 | |
|
UUD1 U30 / UM48F N30
UU
|
LG | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.60 | 13.40 | 9.50 | ||
|
UUD3 U30 / UM48F N30
UU
|
LG | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.60 | 13.40 | 9.50 | ||
|
UUD1 U30 / UM48F N31
UU
|
LG | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.60 | 13.40 | 9.50 | ||
|
UUD3 U30 / UM48F N31
UU
|
LG | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.60 | 13.40 | 9.50 | ||
|
CU-Z42XKE / CS-Z42XKEW
2021
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.68 | -15° | 4.20 | 3.60 | |
|
4MXM80A9 / FTXM35R / FTXM42R
4MXM
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.23 | 3.56 | -15° | 7.70 | 4.27 | |
|
4MXM80A9 / FTXM35A / FTXM42A
4MXM
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.23 | 3.56 | -15° | 7.70 | 4.27 | |
|
S24EC U24 / S24EC NSK
U24A
|
LG | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24SC U24 / PC24SC NSK
U24A
|
LG | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
CU-RZ35WKE / CS-RZ35WKEW
2019
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
SRC50ZSX-W3/FDE50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.07 | 3.70 | -20° | 5.00 | 3.80 | |
|
RAC-VJ60NHAE / RAI-VJ60RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.21 | 3.75 | -10° | 6.00 | 4.70 | |
|
SUZ-M71VA/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
42QZL036D8S*/38QUS036D8T*
Ceiling suspended
|
CARRIER | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
42HU36VDS8C/38HU36VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
SC210HIDS8/AIC210HIDT8
Ceiling suspended
|
RIELLO | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
Vitoclima100-SPROIFCAA100MFP105/Vitoclima100-SPROOFAA100TFP105
Ceiling suspended
|
Viessmann | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
AOEH12KNCA/ASEH12KNCA
ASE**K
|
FUJITSU | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.73 | -15° | 3.40 | 2.50 | |
|
AOHH12KNCA/ASHH12KNCA
ASH**K
|
GENERAL | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.73 | -15° | 3.40 | 2.50 | |
|
AOYH12KNCA/ASYH12KNCA
ASY**K
|
FUJITSU | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.73 | -15° | 3.40 | 2.50 | |
|
ROH12KNCA/RSH12KNCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.73 | -15° | 3.40 | 2.50 | |
|
AOHH12KNCA/ASHH12KNCH
ASH**K
|
GENERAL | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.73 | -15° | 3.40 | 2.50 | |
|
AOYH12KNCA/ASYH12KNCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.73 | -15° | 3.40 | 2.50 | |
|
ARXC50E / ATXC50E
ARXC
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.40 | 3.71 | -14° | 5.10 | 3.90 | |
|
CU-Z60UBEA / CS-Z60UD3EAW
2017
|
PANASONIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.24 | -15° | 6.00 | 4.60 | |
|
GWHD(21)NK6OO GWH09AGCXB-K6DNA1G/I+GWH12AGCXD-K6DNA1D/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.00 | 3.60 | -10° | 6.10 | 6.10 | |
|
4U105S2LS1FA/AS50PDPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 10.50 | 7.50 | |
|
RZAG100NV1 / FAA100B
RZAG
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.42 | 4.01 | 3.17 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FAA100B
RZAG
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.42 | 4.01 | 3.17 | -10° | 9.50 | 7.80 | |
|
GWH18ACD-K6DNA1I
MONOSPLITS
|
GREE | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.90 | -10° | 5.20 | 4.20 | |
|
FDC100VNA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
ADH125H1ERG/1U125S2SN3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.43 | 12.40 | 8.00 | ||
|
MOD30U-36HFN8-QRD0W(GA)/MCD1-36HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 |