Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(0)
AUX
(0)
BOSCH
(3)
BRYANT
(0)
Buderus
(0)
CARRIER
(2)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(5)
GSS
(0)
HAIER
(6)
HEC
(0)
HEIWA
(0)
HISENSE
(12)
HITACHI
(0)
IVT
(2)
Inventor
(0)
KAYSUN
(1)
LG
(0)
MIDEA
(9)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(0)
NORD
(2)
Nobu
(0)
PANASONIC
(8)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(1)
TOSHIBA
(0)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AF50S2SD1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.24 | -10° | 5.00 | 3.40 | |
|
AUW52U4RS7/AKT52UR4RK8
Super Inverter R32
|
HISENSE | Console | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.50 | -10° | 4.90 | 3.50 | |
|
AF50S2SD1FA(D)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.24 | -10° | 5.00 | 3.40 | |
|
AUW40U4RS7/AKT40UR4RK8
Super Inverter R32
|
HISENSE | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.54 | -10° | 4.10 | 3.50 | |
|
AUW35U4RS8/AKT35UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.78 | -10° | 3.50 | 3.00 | |
|
AF35S2SD1FA/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(D)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
NAGANO CONSOLE IC35V3-NG / E1U35LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AUW26U4RS8/AKT26UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.40 | 4.00 | -10° | 2.60 | 3.00 | |
|
MOX230-09HFN8-QRD0W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
KUE-26 DVR14/KSD-26 DR14-2
Console R32
|
KAYSUN | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
AUW40U4RJ8/AKT40UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.71 | -10° | 4.10 | 3.50 | |
|
AUW52U4RJ8/AKT52UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.50 | -10° | 4.90 | 3.50 | |
|
CU-Z50UBEA / CS-Z50UFEAW
2018
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
CU-Z50CBEA / CS-Z50CFEAW
2025
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
42QZY018D8S*/38QUS018D8S*
Console
|
CARRIER | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
42HC18VDS8C*/38HU18VDS8C*
Console
|
CIAT | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
CC250HIDS8*/AIC250HIDS8*
Console
|
RIELLO | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
Vitoclima100-SICNAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Console
|
Viessmann | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
42QZY012D8S*/38QUS012D8S*
Console
|
CARRIER | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42HC12VDS8C*/38HU12VDS8C*
Console
|
CIAT | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
CC235HIDS8*/AIC235HIDS8*
Console
|
RIELLO | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
Vitoclima100-SICNAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Console
|
Viessmann | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
AUV140UR4RC8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.30 | 2.90 | -10° | 13.50 | 9.00 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
AUV125UR4RC8/AUW125U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.30 | 3.65 | -10° | 12.10 | 9.00 | |
|
GUD100ZD1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
M2OF-18HFN8-Q/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
MOX230-09HFN8-QRD6W(GA)/MFA2U-09HRFN8-QRD6W(GA)
Console R32
|
MIDEA | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
MOX230-09AFN8-QRD6W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
MOX230-09HFN8-QRD6W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
CL5100i CNO 25 HE / CL5100i CN 25 HE
Climate 5100i
|
BOSCH | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
Aero 503 O CN / Aero 503 I CN
Aero 500
|
IVT | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
MOX430-12HFN8-QRD6W(GA)/MFA2U-12HRFN8-QRD6W(GA)
Console R32
|
MIDEA | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
MOX430-12AFN8-QRD6W(GA)/MFA2U-12HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
MOX430-12HFN8-QRD6W(GA)/MFA2U-12HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
CL5100i CNO 35 HE / CL5100i CN 35 HE
Climate 5100i
|
BOSCH | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
Aero 504 O CN / Aero 504 I CN
Aero 500
|
IVT | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
NF35DBAHRA/1N35MEAFRA
NORD - Console
|
NORD | Console | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.60 | |
|
GUD50ZD1/A-S/GUD50W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | -10° | 5.30 | 3.90 | ||
|
CU-Z25CBEA / CS-Z25CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.60 | 4.47 | -15° | 2.50 | 2.70 | |
|
CU-Z35CBEA / CS-Z35CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.60 | 3.98 | -15° | 3.50 | 3.20 | |
|
CU-Z35UFEA-1 / CS-Z35UFEAW-1
2018
|
PANASONIC | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.06 | -25° | 3.50 | 3.60 | |
|
CU-Z35CFEA-1 / CS-Z35CFEAW-1
2025
|
PANASONIC | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.06 | -25° | 3.50 | 3.60 | |
|
AUV140UR4RC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 |