Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(0)
AUX
(0)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CARRIER
(4)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(93)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(14)
Fujitsu Atlantic
(7)
GENERAL
(7)
GREE
(2)
GSS
(0)
HAIER
(16)
HEC
(0)
HEIWA
(0)
HISENSE
(41)
HITACHI
(14)
IVT
(2)
Inventor
(2)
KAYSUN
(3)
LG
(5)
MIDEA
(20)
MITSUBISHI ELECTRIC
(39)
Mitsubishi Heavy Industries
(27)
NORD
(7)
Nobu
(0)
PANASONIC
(20)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(2)
TOSHIBA
(11)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AF50S2SD1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.24 | -10° | 5.00 | 3.40 | |
|
AUW52U4RS7/AKT52UR4RK8
Super Inverter R32
|
HISENSE | Console | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.50 | -10° | 4.90 | 3.50 | |
|
SUZ-M60VA/SEZ-M60DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA/SEZ-M60DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/SEZ-M60DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
AF50S2SD1FA(D)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.24 | -10° | 5.00 | 3.40 | |
|
AUW40U4RS7/AKT40UR4RK8
Super Inverter R32
|
HISENSE | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.54 | -10° | 4.10 | 3.50 | |
|
AUW35U4RS8/AKT35UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.78 | -10° | 3.50 | 3.00 | |
|
AF35S2SD1FA/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(D)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
NAGANO CONSOLE IC35V3-NG / E1U35LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AUW26U4RS8/AKT26UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.40 | 4.00 | -10° | 2.60 | 3.00 | |
|
AD105S2SM3FA/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM3FA(H)/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM9FA(H)/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
MOX230-09HFN8-QRD0W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
KUE-26 DVR14/KSD-26 DR14-2
Console R32
|
KAYSUN | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
AUW40U4RJ8/AKT40UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.71 | -10° | 4.10 | 3.50 | |
|
AUW52U4RJ8/AKT52UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.50 | -10° | 4.90 | 3.50 | |
|
CU-Z50UBEA / CS-Z50UFEAW
2018
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
CU-Z50CBEA / CS-Z50CFEAW
2025
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
42QZY018D8S*/38QUS018D8S*
Console
|
CARRIER | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
42HC18VDS8C*/38HU18VDS8C*
Console
|
CIAT | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
CC250HIDS8*/AIC250HIDS8*
Console
|
RIELLO | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
Vitoclima100-SICNAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Console
|
Viessmann | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
42QZY012D8S*/38QUS012D8S*
Console
|
CARRIER | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42HC12VDS8C*/38HU12VDS8C*
Console
|
CIAT | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
CC235HIDS8*/AIC235HIDS8*
Console
|
RIELLO | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
Vitoclima100-SICNAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Console
|
Viessmann | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
RXM25R9 / FNA25A9
RXM
|
DAIKIN | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.60 | 2.80 | |
|
RXM25R9 / FDXM25F9
RXM
|
DAIKIN | Ducted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.40 | 2.60 | |
|
RAV-GM302ATP-E/RAV-HM301SDTY-E
DI
|
TOSHIBA | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.21 | 3.95 | -15° | 2.50 | 2.60 | |
|
AD105S2SM3FA/1U105S2SS2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 9.50 | 7.20 | |
|
CU-Z25UBEA / CS-Z25UD3EAW
2017
|
PANASONIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.90 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
AD35S2SM3FA/1U35S2SM1FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 3.50 | 2.70 | |
|
NAGANO GAINABLE MP IG35MP-NG / E1U35LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 3.50 | 2.70 | |
|
AUV140UR4RC8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.30 | 2.90 | -10° | 13.50 | 9.00 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
AD71S2SM3FA/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.06 | 4.47 | 3.34 | -10° | 6.80 | 5.00 | |
|
PUZ-ZM60VHA2/SEZ-M60DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/SEZ-M60DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 |