Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(0)
AUX
(0)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CARRIER
(5)
CIAT
(3)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(157)
EQUATION
(0)
FUJI ELECTRIC
(6)
FUJITSU
(20)
Fujitsu Atlantic
(9)
GENERAL
(9)
GREE
(2)
GSS
(0)
HAIER
(23)
HEC
(0)
HEIWA
(0)
HISENSE
(39)
HITACHI
(14)
IVT
(2)
Inventor
(2)
KAYSUN
(3)
LG
(19)
MIDEA
(20)
MITSUBISHI ELECTRIC
(55)
Mitsubishi Heavy Industries
(64)
NORD
(7)
Nobu
(0)
PANASONIC
(36)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(11)
THERMOR
(2)
TOSHIBA
(34)
Viessmann
(5)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC25S2SG1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 2.50 | 2.80 | |
|
AF50S2SD1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.24 | -10° | 5.00 | 3.40 | |
|
AUW52U4RS7/AKT52UR4RK8
Super Inverter R32
|
HISENSE | Console | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.50 | -10° | 4.90 | 3.50 | |
|
RAV-GM561ATP-E1/RAV-HM561CTP-E
DI
|
TOSHIBA | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.61 | 4.32 | 3.90 | -15° | 5.00 | 2.80 | |
|
FDC140VNA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
RAV-GM562ATP-E/RAV-HM561CTP-E
DI
|
TOSHIBA | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.34 | 3.90 | -15° | 5.00 | 2.80 | |
|
SUZ-M60VA/SEZ-M60DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA/SEZ-M60DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/SEZ-M60DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
AF50S2SD1FA(D)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.24 | -10° | 5.00 | 3.40 | |
|
AUW40U4RS7/AKT40UR4RK8
Super Inverter R32
|
HISENSE | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.54 | -10° | 4.10 | 3.50 | |
|
AUW35U4RS8/AKT35UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.78 | -10° | 3.50 | 3.00 | |
|
RAV-GM1402AT8W-E/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.20 | 3.79 | -15° | 12.10 | 8.00 | |
|
FDC125VNP-W/FDE125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.95 | 4.21 | 3.67 | 12.10 | 7.90 | ||
|
RAV-GM801ATP-E/RAV-HM801CTP-E
DI
|
TOSHIBA | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.21 | 3.62 | -15° | 6.90 | 5.10 | |
|
AF35S2SD1FA/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(D)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
NAGANO CONSOLE IC35V3-NG / E1U35LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AUW26U4RS8/AKT26UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.40 | 4.00 | -10° | 2.60 | 3.00 | |
|
AD105S2SM3FA/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM3FA(H)/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM9FA(H)/1U105S2SS1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
UUC1 U40 / UV36F N20
U4
|
LG | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.70 | -10° | 9.50 | 5.50 | |
|
AC71S2SG1FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 7.10 | 5.00 | |
|
MOX230-09HFN8-QRD0W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
KUE-26 DVR14/KSD-26 DR14-2
Console R32
|
KAYSUN | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
FDC71VNP-W/FDE71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.74 | 4.32 | 3.62 | -15° | 7.10 | 5.70 | |
|
AUW40U4RJ8/AKT40UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.71 | -10° | 4.10 | 3.50 | |
|
AUW52U4RJ8/AKT52UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.50 | -10° | 4.90 | 3.50 | |
|
RAV-GM1101ATP-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
FDC125VSA/FDE125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
FDC250VSA/FDE125VH/FDE125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.45 | 3.58 | 24.00 | 14.20 | ||
|
FDC125VNA/FDE125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
FDC125VNA-W/FDE125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDE125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
CU-Z50UBEA / CS-Z50UFEAW
2018
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
CU-Z50CBEA / CS-Z50CFEAW
2025
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 |