Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(78)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(3)
FUJITSU
(9)
Fujitsu Atlantic
(3)
GENERAL
(3)
GREE
(0)
GSS
(0)
HAIER
(7)
HEC
(0)
HEIWA
(0)
HISENSE
(10)
HITACHI
(7)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(14)
MIDEA
(3)
MITSUBISHI ELECTRIC
(25)
Mitsubishi Heavy Industries
(57)
NORD
(0)
Nobu
(0)
PANASONIC
(16)
PITSOS
(0)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(6)
THERMOR
(0)
TOSHIBA
(27)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC25S2SG1FA(H)/1U25S2SM1FA-2
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 2.50 | 2.80 | |
|
SUZ-M25VA2/MFZ-KT25VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.71 | -10° | 2.50 | 2.20 | |
|
RAV-GM561ATP-E1/RAV-HM561CTP-E
DI
|
TOSHIBA | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.61 | 4.32 | 3.90 | -15° | 5.00 | 2.80 | |
|
FDC140VNA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
RAV-GM562ATP-E/RAV-HM561CTP-E
DI
|
TOSHIBA | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.34 | 3.90 | -15° | 5.00 | 2.80 | |
|
RAC-25NPE / RAD-25RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.84 | |
|
RAC-25NPE / RAI-25RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.84 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 | |
|
AC026BXAPKG/AC026BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.33 | -25° | 2.60 | 2.00 | |
|
RAV-GM1402AT8W-E/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.20 | 3.79 | -15° | 12.10 | 8.00 | |
|
FDC125VNP-W/FDE125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.95 | 4.21 | 3.67 | 12.10 | 7.90 | ||
|
SUZ-M60VA/SFZ-M60VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/SFZ-M60VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 6.10 | 4.60 | |
|
RAV-GM801ATP-E/RAV-HM801CTP-E
DI
|
TOSHIBA | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.21 | 3.62 | -15° | 6.90 | 5.10 | |
|
RAC-35NPE / RAI-35RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.81 | -15° | 3.50 | 2.84 | |
|
RAC-35NPE / RAD-35RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.81 | -15° | 3.50 | 2.84 | |
|
UUC1 U40 / UV36F N20
U4
|
LG | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.70 | -10° | 9.50 | 5.50 | |
|
AC71S2SG1FA(H)/1U71S2SR2FA
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 7.10 | 5.00 | |
|
RAV-GP561ATW-E/RAV-HM561FT-E
SDI
|
TOSHIBA | Floor standing | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.21 | 3.39 | -27° | 5.00 | 3.80 | |
|
FDC250VSA/FDF125VD/FDF125VD
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.45 | 4.25 | 3.18 | 24.00 | 14.20 | ||
|
FDC71VNP-W/FDE71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.74 | 4.32 | 3.62 | -15° | 7.10 | 5.70 | |
|
RAV-GM1101ATP-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
FDC125VSA/FDE125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
FDC250VSA/FDE125VH/FDE125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.45 | 3.58 | 24.00 | 14.20 | ||
|
FDC125VNA/FDE125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
FDC125VNA-W/FDE125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDE125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
SUZ-M35VA/MFZ-KT35VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.41 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/MFZ-KT35VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.41 | -10° | 3.50 | 2.60 | |
|
RAV-GM1602AT8W-E/RAV-HM1601CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.22 | 3.41 | -15° | 14.00 | 8.00 | |
|
SUZ-M50VA/MFZ-KT50VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/MFZ-KT50VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.21 | -10° | 5.00 | 4.30 | |
|
U-71PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.30 | 4.20 | -15° | 6.80 | 4.70 | |
|
RXM35R9 / FHA35A9
RXM
|
DAIKIN | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.43 | 4.08 | -15° | 3.40 | 3.10 | |
|
FDC250VSA-W/FDF125VH/FDF125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
FDC250VSA-W/FDF125VH1/FDF125VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
AUW71U4RJ7/AVT71UR4RB8
Super Inverter R32
|
HISENSE | Ceiling suspended | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.20 | 3.72 | -10° | 7.00 | 5.50 | |
|
AC71S2SG1FA(H)/1U71S2ST1FA
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.20 | 3.52 | -10° | 7.10 | 5.00 | |
|
RAV-GM1402ATW-E/RAV-HM1401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.28 | 3.74 | -15° | 12.10 | 8.00 | |
|
UUB1 U20 / UV24F N10
UU
|
LG | Ceiling suspended | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.28 | -10° | 6.80 | 4.30 | |
|
PUZ-ZM50VKA2/PCA-M50KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 4.04 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PCA-M50KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 4.04 | -11° | 5.00 | 3.80 | |
|
RZAG60B / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -10° | 6.00 | 4.60 | |
|
AUV140UR4RC8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.30 | 2.90 | -10° | 13.50 | 9.00 |