Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(84)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(16)
HITACHI
(4)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(3)
MIDEA
(0)
MITSUBISHI ELECTRIC
(4)
Mitsubishi Heavy Industries
(30)
NORD
(1)
Nobu
(0)
PANASONIC
(11)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(10)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.57 | 12.10 | 6.00 | |||
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RAV-GM901ATP-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
PUZ-SM125YKA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
RAV-GM401ATP-E/RAV-HM401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.34 | 5.10 | 5.13 | -15° | 3.60 | 2.70 | |
|
UUA1 UL0 / UV18F N10
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 3.70 | -10° | 5.00 | 2.90 | |
|
SRC35ZS-W2/SRR35ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.50 | 4.16 | -10° | 3.50 | 3.10 | |
|
RAV-GM901ATP-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
FDC200VSA-W/FDE100VH/FDE100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.53 | 3.96 | 20.00 | 12.50 | ||
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
FDC250VSA/FDUM125VH/FDUM125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.50 | 3.59 | 24.00 | 14.20 | ||
|
RZAG100NV1 / FUA100A
RZAG
|
DAIKIN | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.50 | 4.03 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FUA100A
RZAG
|
DAIKIN | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.50 | -10° | 9.50 | 7.80 | ||
|
RZAG100NV1 / FHA100A
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.61 | 3.97 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FHA100A
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.61 | -10° | 9.50 | 7.80 | ||
|
FDC140VSA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC125VNA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC200VSA-W/FDUM100VH/FDUM100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.57 | 4.64 | 4.01 | 20.00 | 12.50 | ||
|
RAV-GM902ATW-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.60 | 4.00 | -15° | 8.00 | 6.30 | |
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
UUC1 U40 / UV30FH N20
U4
|
LG | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.60 | 3.72 | -10° | 8.00 | 5.40 | |
|
AUD140UX4RQM8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.85 | 4.50 | 3.72 | -10° | 13.50 | 9.00 | |
|
AUD140UX4RQM8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.85 | 4.50 | 3.72 | -10° | 13.50 | 9.00 | |
|
RZAG100NV1 / FHA50A9 / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.75 | 4.54 | 4.54 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FHA50A9 / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.75 | 4.54 | 4.54 | -10° | 9.50 | 7.80 | |
|
RZASG140MV1
RZASG
|