Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(1)
AUX
(0)
BOSCH
(26)
BRYANT
(0)
Buderus
(6)
CARRIER
(9)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(119)
EQUATION
(0)
FUJI ELECTRIC
(9)
FUJITSU
(24)
Fujitsu Atlantic
(15)
GENERAL
(30)
GREE
(2)
GSS
(0)
HAIER
(7)
HEC
(0)
HEIWA
(0)
HISENSE
(24)
HITACHI
(8)
IVT
(2)
Inventor
(2)
KAYSUN
(0)
LG
(12)
MIDEA
(17)
MITSUBISHI ELECTRIC
(26)
Mitsubishi Heavy Industries
(37)
NORD
(0)
Nobu
(0)
PANASONIC
(32)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(14)
THERMOR
(0)
TOSHIBA
(35)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AR70F09CABWN/AR70F09CABWX
RAC
|
SAMSUNG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR50H09C1BHN/AR50H09C1BHX
RAC
|
SAMSUNG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
RXA25A9 / FTXA25AW
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -15° | 2.50 | 2.45 | |
|
RXA25A9 / FTXA25BB
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -15° | 2.50 | 2.45 | |
|
RXA25A9 / FTXA25BS
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -15° | 2.50 | 2.45 | |
|
RXA25A9 / FTXA25BT
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -15° | 2.50 | 2.45 | |
|
RAS-13P2AVSG-E/RAS-B13N4KVRG-E1
HAORI
|
TOSHIBA | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
RXM25A / FTXM25A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.50 | 2.40 | |
|
NH09SP2 U24A / NH09SP2 NS2
U24A
|
LG | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 5.42 | -10° | 2.50 | 3.80 | |
|
RXA20A9 / FTXA20AW
RXA
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -15° | 2.00 | 2.40 | |
|
RXA20A9 / FTXA20BB
RXA
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -15° | 2.00 | 2.40 | |
|
RXA20A9 / FTXA20BS
RXA
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -15° | 2.00 | 2.40 | |
|
RXA20A9 / FTXA20BT
RXA
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -15° | 2.00 | 2.40 | |
|
AOYG12KGCB/ASYG12KGTF
ASY**K
|
FUJITSU | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
AOHG12KGCB/ASHG12KGTF
ASH**K
|
GENERAL | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
ROG12KGCB/RSG12KGTF
RS**K
|
FUJI ELECTRIC | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
AOYG12KGCB/ASYG12KGTF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
AR70H09CAAWN/AR70H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR70H09CAABN/AR70H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
RXM20A / FTXM20A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.00 | 2.30 | |
|
RXM20A / FTXM20A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.00 | 2.30 | |
|
FDC140VNX-W/FDT71VH/FDT71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 5.07 | 4.40 | 14.00 | 13.00 | ||
|
MUZ-FH25VE/MSZ-FH25VE2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 5.52 | -15° | 2.50 | 3.00 | |
|
SRC20ZSX-W/SRK20ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.20 | 5.74 | -10° | 2.00 | 2.80 | |
|
SRC20ZSX-W/SRK20ZSX-WF
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.20 | 5.74 | -10° | 2.00 | 2.80 | |
|
SRC20ZSX-W/SRK20ZSX-WFB
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.20 | 5.74 | -10° | 2.00 | 2.80 | |
|
SRC20ZSX-W/SRK20ZSX-WFT
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.20 | 5.74 | -10° | 2.00 | 2.80 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 5.09 | 12.10 | 6.00 | ||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 5.09 | 12.10 | 6.00 | ||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 12.10 | 6.00 | |||
|
SRC25ZSX-W/SRK25ZSX-WF
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.30 | 5.20 | 5.42 | -10° | 2.50 | 3.00 | |
|
SRC25ZSX-W/SRK25ZSX-WFB
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.30 | 5.20 | 5.42 | -10° | 2.50 | 3.00 | |
|
SRC25ZSX-W/SRK25ZSX-WFT
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.30 | 5.20 | 5.42 | -10° | 2.50 | 3.00 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.89 | 5.03 | 5.03 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.89 | 5.03 | 5.03 | 13.40 | 9.52 | ||
|
RAV-GM402ATP-E/RAV-HM401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 5.13 | 5.13 | -15° | 3.60 | 2.70 | |
|
FDC125VNX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 5.10 | 3.10 | 12.50 | 11.40 | ||
|
CL9100i 85 E / CL9100i-W 85 E
Climate 9100i
|
BOSCH | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 5.37 | -25° | 3.50 | 4.00 | |
|
AOYH09KJCA/ASYH09KJCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
AOYH09KJCA/ASYH09KJCA-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
AOHH09KJCA/ASHH09KJCA
ASH**K
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
AOHH09KJCA/ASHH09KJCA-B
ASH**K
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
AOEH09KJCA/ASEH09KJCAL
ASE**K
|
FUJITSU | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
AOEH09KJCA/ASEH09KJCALB
ASE**K
|
FUJITSU | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
AOHH09KJCA/ASHH09KJCAL
ASH**K
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
AOHH09KJCA/ASHH09KJCALB
ASH**K
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.67 | -20° | 2.50 | 2.40 | |
|
CU-VZ12SKE / CS-VZ12SKE
2016
|
PANASONIC | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.90 | 5.06 | -10° | 3.50 | 4.20 | |
|
RZASG140MV1
RZASG
|
DAIKIN | Ceiling suspended | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.88 | 5.13 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ceiling suspended | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.88 | 5.13 | 13.40 | 7.80 |