Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(37)
AUX
(144)
BOSCH
(136)
BRYANT
(6)
Buderus
(38)
CARRIER
(155)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(702)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(129)
FUJITSU
(303)
Fujitsu Atlantic
(153)
GENERAL
(202)
GREE
(139)
GSS
(4)
HAIER
(453)
HEC
(5)
HEIWA
(8)
HISENSE
(406)
HITACHI
(144)
IVT
(10)
Inventor
(138)
KAYSUN
(68)
LG
(306)
MIDEA
(796)
MITSUBISHI ELECTRIC
(490)
Mitsubishi Heavy Industries
(298)
NORD
(56)
Nobu
(8)
PANASONIC
(301)
PITSOS
(6)
RIELLO
(46)
Rotenso
(3)
SAMSUNG
(190)
THERMOR
(54)
TOSHIBA
(246)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(39)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RXTM30A / FVXTM30B
RXTM
|
DAIKIN | Floor standing | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.75 | 4.44 | -30° | 3.00 | 3.00 | |
|
FDC90VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
RXD35A / FTXD35A
RXD
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 3.98 | -20° | 3.30 | 2.50 | |
|
RAS-10P2AVSG-E/RAS-B10N4KVRG-E2
HAORI
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.57 | -20° | 2.50 | 2.50 | |
|
FDC90VNP-W/FDT100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.56 | 4.74 | -15° | 9.00 | 6.00 | |
|
PUZ-ZM140YDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
U-60PZH3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.70 | 4.12 | -20° | 6.10 | 4.60 | |
|
FDC100VNX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
RZAG100NV1 / FCAG50B / FCAG50B
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.64 | 4.64 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FCAG50B / FCAG50B
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.64 | 4.64 | -10° | 9.50 | 7.80 | |
|
RAS-2M10G3AVG-E/RAS-B10G3KVSG-E+RAS-B07G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAS-2M10G3AVG-E/RAS-B10G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
38WH2M033C1A0TEE/40WHHW025D1A0TEE/40WHHW020D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
38WH2M033C1A0TEE/40WHHW025D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAS-2M10G3AVG-E/RAS-B10P2KVSG-E+RAS-B07P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAS-2M10G3AVG-E/RAS-B10P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
SRC50ZSX-W3/SRR50ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.88 | -10° | 5.00 | 4.50 | |
|
RZAG125NV1 / FCAHG125H
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.02 | 4.53 | 12.10 | 9.52 | |||
|
SCM60ZS-W/SRK25ZSX-W/SRK35ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.20 | 4.70 | 4.86 | -10° | 6.00 | 4.80 | |
|
M2OF-18HFN8-Q/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
RXJ35A / FTXJ35AB
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A / FTXJ35AS
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A / FTXJ35AW
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CB
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CS
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CW
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CS
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CB
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CW
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AW
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AB
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AS
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AW9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AB9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AS9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
SRC60ZSX-W3/SRK60ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.70 | 4.12 | -10° | 6.10 | 5.20 | |
|
SRC60ZSX-W3/SRK60ZSX-WF
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.70 | 4.12 | -10° | 6.10 | 5.20 | |
|
SRC60ZSX-W3/SRK60ZSX-WFB
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.70 | 4.12 | -10° | 6.10 | 5.20 | |
|
SRC60ZSX-W3/SRK60ZSX-WFT
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.70 | 4.12 | -10° | 6.10 | 5.20 | |
|
U-71PZ3E5A / S-6071PU3E
2021
|
PANASONIC | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.60 | 4.23 | -15° | 7.10 | 5.20 | |
|
RXD25A / FTXD25A
RXD
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.59 | -20° | 2.50 | 2.40 |