Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(1)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(125)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(6)
HEC
(0)
HEIWA
(0)
HISENSE
(24)
HITACHI
(9)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(4)
MIDEA
(0)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(24)
NORD
(5)
Nobu
(0)
PANASONIC
(18)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(11)
THERMOR
(0)
TOSHIBA
(9)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.32 | 3.89 | 3.89 | 19.00 | 11.20 | ||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.64 | 3.85 | 3.85 | 19.00 | 11.20 | ||
|
RZA200D
RZA
|
DAIKIN | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.85 | 3.82 | 19.00 | 11.20 | |||
|
RZA250D
RZA
|
DAIKIN | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.08 | 3.86 | 22.00 | 12.10 | |||
|
RZA200D
RZA
|
DAIKIN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.01 | 3.90 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.01 | 3.90 | 19.00 | 11.20 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.80 | 3.90 | 12.10 | 9.00 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.80 | 3.90 | 12.10 | 9.00 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.80 | 3.90 | 12.10 | 9.00 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.80 | 3.90 | 12.10 | 9.00 | |||
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
AC 018 DB.UI/1U 018 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.00 | 3.71 | -10° | 5.20 | 4.40 | |
|
RZASG100MV1 / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MV1 / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
AC50S2SG1FA/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC50S2SG1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
RPIH-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.86 | -15° | 7.30 | 6.00 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.83 | 3.93 | 19.00 | 11.20 | |||
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
AC50S2SG2FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.31 | 4.10 | 3.73 | -10° | 5.00 | 4.40 | |
|
YDAM-050R-09M25/FDHM-050N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.31 | 4.10 | 3.73 | -10° | 5.00 | 4.40 | |
|
RAS-3HVRC3 / RPC-3.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.09 | 3.73 | -25° | 7.10 | 6.00 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.01 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.15 | 19.00 | 11.20 | |||
|
AC35S2SG1FA/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC35S2SG1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
RZAG125NY1 / FHA125A
RZAG
|
DAIKIN | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.20 | 12.10 | 9.52 | |||
|
RZAG125NV1 / FHA125A
RZAG
|
DAIKIN | Ceiling suspended | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.20 | 12.10 | 9.52 | |||
|
RZAG71NV1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RAS-2.5HVRC3 / RPC-2.5FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.05 | 3.72 | -25° | 5.60 | 5.20 | |
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.42 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.42 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.42 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.42 | 12.10 | 6.00 | |||
|
U-36PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.61 | -15° | 3.50 | 2.80 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.43 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.43 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.43 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.43 | 12.10 | 6.00 |